The Influence of Different Types of Switching Sequences in Space-Vector PWM on Output Characteristics of Three-Level Voltage Inverter

Authors:

Abstract
This article studies the impact of various switching sequence types on the operation of a three-level neutral point clamped voltage source inverter during space-vector PWM. The authors reviewed three common sequences: standard, seven-stage, and five-stage. The sequences were compared using four criteria: the quality of the inverter output curve, the balance of the neutral point voltage, the common-mode voltage, and the mitigation of the switching losses. To assess the data for three of the sequences, the authors developed a computer model using Matlab & Simulink. The analysis of the results helps select the best switching sequence taking into account the operational requirements of the inverter, while the seven-stage sequence assures acceptable results for all four of the criteria used. The results provided in this article can be used for the design of electric drive systems that require high efficiency and reliability, as well as further research on three-level voltage inverters.