Intraobserver Repeatability and Interobserver Reproducibility of Ellipsoid Zone Measurements in Retinitis Pigmentosa
Open Access
- 1 May 2018
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 7 (3) , 13
Abstract
Purpose: To examine repeatability and reproducibility of ellipsoid zone (EZ) width measurements in patients with retinitis pigmentosa (RP) using a longitudinal reflectivity profile (LRP) analysis. Methods: We examined Bioptigen optical coherence tomography (OCT) scans from 48 subjects with RP or Usher syndrome. Nominal scan lengths were 6, 7, or 10 mm, and the lateral scale of each scan was calculated using axial length measurements. LRPs were generated from OCT line scans, and the peak corresponding to EZ was manually identified using ImageJ. The locations at which the EZ peak disappeared were used to calculate EZ width. Each scan was analyzed twice by each of two observers, who were masked to their previous measurements and those of the other observer. Results: On average, horizontal width (HW) was significantly greater than vertical width (VW), and there was high interocular symmetry for both HW and VW. We observed excellent intraobserver repeatability with intraclass correlation coefficients (ICCs) ranging from 0.996 to 0.998 for HW and VW measurements. Interobserver reproducibility was also excellent for both HW (ICC = 0.989; 95% confidence interval [CI] = 0.983–0.995) and VW (ICC = 0.991; 95% CI = 0.985–0.996), with no significant bias observed between observers. Conclusions: EZ width can be measured using LRPs with excellent repeatability and reproducibility. Our observation of greater HW than VW is consistent with previous observations in RP, though the reason for this anisotropy remains unclear. Translational Relevance: We describe repeatability and reproducibility of a method for measuring EZ width in patients with RP or Usher syndrome. This approach could facilitate measurement of retinal band thickness and/or intensity.Keywords
This publication has 48 references indexed in Scilit:
- SELECTIVE CONE PHOTORECEPTOR INJURY IN ACUTE MACULAR NEURORETINOPATHYRetina, 2013
- Repeatability of In Vivo Parafoveal Cone Density and Spacing MeasurementsOptometry and Vision Science, 2012
- The Inner Segment/Outer Segment Border Seen on Optical Coherence Tomography Is Less Intense in Patients with Diminished Cone FunctionInvestigative Ophthalmology & Visual Science, 2011
- Transition Zones between Healthy and Diseased Retina in Choroideremia (CHM) and Stargardt Disease (STGD) as Compared to Retinitis Pigmentosa (RP)Investigative Ophthalmology & Visual Science, 2011
- ANATOMICAL CORRELATES TO THE BANDS SEEN IN THE OUTER RETINA BY OPTICAL COHERENCE TOMOGRAPHYRetina, 2011
- Method for deriving visual field boundaries from OCT scans of patients with retinitis pigmentosaBiomedical Optics Express, 2011
- Longitudinal Study of Cone Photoreceptors during Retinal Degeneration and in Response to Ciliary Neurotrophic Factor TreatmentInvestigative Ophthalmology & Visual Science, 2011
- ARTIFACTS IN AUTOMATIC RETINAL SEGMENTATION USING DIFFERENT OPTICAL COHERENCE TOMOGRAPHY INSTRUMENTSRetina, 2010
- Retinal imaging using commercial broadband optical coherence tomographyBritish Journal of Ophthalmology, 2009
- Applying the right statistics: analyses of measurement studiesUltrasound in Obstetrics & Gynecology, 2003