Effect of refractive surgery on Maklakov tonometry results
- 23 April 2024
- journal article
- abstracts
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 140 (2) , 51-59
Abstract
PURPOSE The study investigates the influence of changes in keratometric parameters after refractive surgery on the results of Maklakov tonometry. MATERIAL AND METHODS The study examined a total of 61 people (121 eyes). The patients were divided into a control group with no history of surgery (16 people, 31 eyes), a LASIK group (13 people, 26 eyes), a femtosecond-assisted LASIK (FS-LASIK) group (16 people, 32 eyes), and a photorefractive keratectomy (PRK) group (16 people, 32 eyes). The patients underwent standard examination, keratometry (Km), Maklakov tonometry with a 10 g weight, and elastotonometry with 5, 7.5, and 15 g weights. RESULTS In the LASIK group, the indentation diameter with 5 and 7.5 g weights correlated with Km in the central and near-paracentral zone (r=0.3—0.5). Tonometry with a 10 g weight did not correlate with anything. Tonometry with a 15 g weight inversely correlated with Km in the paracentral points (4 mm) of the strong meridian (r= –0.5 ... –0.7). In the FS-LASIK group, a significant inverse correlation with Km was observed only for the indentation diameter with a 10 g weight in the paracentral (3—4 mm) zone (r= –0.4 ... –0.5). In the PRK group, weak (rr= –0.38 ... –0.60), the indentation of the 15 g weight correlated mainly with the curvature of the horizontal meridian (r= –0.37 ... –0.49). CONCLUSION Tonometry readings with the 10 g weight are the most dependent on Km in different groups, and the readings with the 5 g weight are the least dependent. LASIK is characterized by the largest scatter of dependencies for weights of different masses, FS-LASIK — by the smallest. Tonometry readings with the 5 g weight correlated with Km only in the LASIK group, and this was the only direct correlation. Considering the inverse nature of most correlations, higher Km may be associated with an overestimation of tonometry results, and lower Km — with its underestimation.Keywords
This publication has 8 references indexed in Scilit:
- Refractive surgery beyond 2020Eye, 2020
- New applanation tonometer for myopic patients after laser refractive surgeryScientific Reports, 2020
- Elastotonometry for evaluation of biomechanical characteristics of the eye after surgical hyperopia correctionRussian Annals of Ophthalmology, 2020
- Refractive surgeryThe Lancet, 2019
- Changes in biomechanically corrected intraocular pressure and dynamic corneal response parameters before and after transepithelial photorefractive keratectomy and femtosecond laser–assisted laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2017
- Corneal Biomechanical Properties in Different Ocular Conditions and New Measurement TechniquesISRN Ophthalmology, 2014
- Postoperative changes in intraocular pressure and corneal biomechanical metricsJournal of Cataract & Refractive Surgery, 2009
- A Correction Formula for the Real Intraocular Pressure After LASIK for the Correction of Myopic AstigmatismJournal of Refractive Surgery, 2006