A comparative study between 10-MHz and 15-MHz ultrasound probes for retinal evaluation in silicone-oil-filled globes
Open Access
- 6 March 2023
- journal article
- research article
- Published by Springer Nature in Eye
- Vol. 37 (14) , 3020-3025
Abstract
Purpose: To compare 10-MHz and 15-MHz B-scan probes regarding the detection and localization of retinal detachment (RD) in silicone-oil-filled eyes. Methods: This cross-sectional observational study included 100 eyes (98 patients) -having media opacity precluding fundus examination- scheduled for silicone-oil removal. Patients were examined in the sitting-position using both frequencies one week preoperatively. Longitudinal and transverse scans were taken in primary-gaze, inferior, inferonasal, and inferotemporal positions to detect the presence/absence and extent of RD. Patients were sub-grouped according to axial lengths (AXLs), state of silicone emulsification, and globe filling. Agreement between sonographic and intraoperative observations was compared. Results: No statistically significant differences were found between 15-MHz and intra-operative findings regarding RD detection (P = 0.752) and accurate localization of inferior, inferonasal, and inferotemporal RD (P = 0.279, 0.606, and 0.599). There were statistically significant differences between 10-MHz and intra-operative findings regarding RD detection and localization (P < 0.001). The 15-MHz probe was superior to 10-MHz probe regarding the accuracy of RD detection and localization (94% and 47%, respectively). The accuracy of 15-MHz probe was 88%, 83%, and 85% in detecting and localizing inferior, inferonasal, and inferotemporal RD compared to 45%, 60%, and 62% with 10-MHz probe. The 15-MHz probe showed better sensitivity while 10-MHz probe showed better accuracy in eyes with short AXLs. The 10-MHz probe showed better sensitivity in patients with sonographic emulsification while15-MHz probe had better sensitivity in detecting vitreoretinal-interface disorders. Conclusion: The 15-MHz B-scan probe is more accurate in detecting and localizing recurrent RD in silicone-oil-filled globes with higher sensitivity in detecting vitreoretinal-interface disorders.Keywords
This publication has 14 references indexed in Scilit:
- Use of ophthalmic B-scan ultrasonography in determining the causes of low vision in patients with diabetic retinopathyEuropean Journal of Radiology Open, 2018
- Development of 15MHz 2-2 piezo-composite ultrasound linear array transducers for ophthalmic imagingSensors and Actuators A: Physical, 2014
- The Results of B-scan Ultrasonography in Different Positions after Vitrectomy and Gas TamponadeKorean Journal of Ophthalmology, 2007
- A comparison of 10 MHz and 20 MHz ultrasound probes in imaging the eye and orbitBritish Journal of Ophthalmology, 2004
- Measurement of axial length of eyes with incomplete filling of silicone oil in the vitreous cavity using x ray computed tomographyBritish Journal of Ophthalmology, 2002
- Biometry of the silicone oil-filled eyeEye, 1999
- Phacoemulsification and silicone oil removal through a single corneal incision11The authors have no proprietary interest in any of the instruments or devices used in this project.Ophthalmology, 1998
- Prone position ultrasonography in silicone filled eyesActa Ophthalmologica Scandinavica, 1998
- [Ultrasonic diagnosis of retinal detachment after internal tamponade with silicone oil].1998
- Ultrasonics in Ocular DiagnosisAmerican Journal of Ophthalmology, 1956