DEXA Measurement of spine density in the lateral projection. I: Methodology
Authors:
- 1 July 1991
- journal article
- research article
- Published by Springer Nature in Calcified Tissue International
- Vol. 49 (4) , 235-239
Abstract
Bone mineral content and bone mineral density (BMC in g and BMD in g/cm2) were measured using dualenergy X-ray absorptiometry (DEXA). DEXA scans in the lateral decubitus position required about 12 minutes for the L2−L4 sequence at 0.75 mA (dose 5 mrem) and 4 minutes at 4.75 mA (7 mrem). The former scans were done with the Lunar DPX densitometer and the latter with the Lunar DPX-L One test of the algorithms used for measurement is the equality of BMC in both AP and lateral projections. BMC in the lateral projection averaged about 1% lower than in the AP projection in phantoms and for L2+L3 in 8 subjects, but the difference was not significant. Additional tests were done on the effects of tissue thickness and position from the tabletop. There was little or no influence of tissue thickness from 18 to 30 cm on BMD results, but there was a small influence of thickness below 18 cm (0.01 g/cm2;P=0.01) and of distance from the tabletop at extremes of positioning (0.02 g/cm2;P=0.06). The precisionin vivo was similar for both 4- and 12-minute scans; the standard deviation of repeat measurements was about 0.02 g/cm2, which was about 2% relative to the mean BMD for a region within the vertebral body. The latter region included half the BMC of the body, or 24% of the entire vertebra. Results of 4-minute scans on the DPX and 12-minute scans on the DPX-L in 9 subjucts were highly correlated (r=0.98;P<0.001).Keywords
This publication has 11 references indexed in Scilit:
- Vertebral bone mineral density measured laterally by dual-energy X-ray absorptiometryOsteoporosis International, 1990
- LATERAL DUAL ENERGY RADIOGRAPHY: A NEW METHOD FOR MEASURING VERTEBRAL BONE DENSITY: A PRELIMINARY STUDYThe Journal of Clinical Endocrinology & Metabolism, 1990
- Lateral dual-photon absorptiometry: A new technique to measure the bone mineral density at the lumbar spineJournal of Bone and Mineral Research, 1990
- The Impact of Osteophytic and Vascular Calcifications on Vertebral Mineral Density Measurements in Men*The Journal of Clinical Endocrinology & Metabolism, 1990
- Bone Densitometry for Diagnosis and Monitoring OsteoporosisExperimental Biology and Medicine, 1989
- Performance evaluation of a dual-energy X-ray bone densitometerCalcified Tissue International, 1989
- Dual-energy radiographic absorptiometry for bone densitometry: current status and perspectiveAmerican Journal of Roentgenology, 1989
- Comparison of Dual-Energy X-Ray Absorptiometry and Dual Photon Absorptiometry for Bone Mineral Measurements of the Lumbar SpineMayo Clinic Proceedings, 1988
- Quantitative Digital RadiographyVersusDual Photon Absorptiometry of the Lumbar Spine*The Journal of Clinical Endocrinology & Metabolism, 1988
- Importance of measurement of spongious vertebral bone mineral density in the assessment of osteoporosisBone, 1987