Femtosecond laser‐assisted cataract surgery compared with conventional cataract surgery
- 10 December 2012
- journal article
- research article
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 41 (5) , 455-462
Abstract
Background: To investigate the safety and efficacy of the Catalys (Optimedica, Santa Clara, CA, USA) femtosecond laser‐assisted cataract surgery system compared with conventional phacoemulsification cataract extraction.Design: Prospective, consecutive, parallel cohort study.Participants: The first 200 eyes undergoing conventional cataract surgery to the first 200 eyes undergoing femtosecond laser‐assisted cataract surgery between April and July 2012.Methods: Femtosecond laser‐assisted cataract surgery involved anterior capsulotomy and lens fragmentation based on optical coherence tomography‐guided treatment mapping. Conventional cataract surgery involved manual continuous curvilinear capsulorhexis. Both procedures were completed by standard phacoemulsification and insertion of an intraocular lens.Main Outcome Measures: Effective phacoemulsification time and intraoperative complication rates.Results: Patient demographics were similar between both groups. There was no statistically significant difference in intraoperative complications between femtosecond laser‐assisted cataract surgery and conventional surgery. There was one posterior capsule rupture in both groups (0.5%; not significant). One hundred per cent of cases treated with the femtosecond laser had a complete capsulotomy. Vacuum time decreased with experience. Effective phacoemulsification time was reduced by 70% in the femtosecond group (P < 0.0001). Twenty‐six cases in the femtosecond group versus one case in the conventional group had 0 effective phacoemulsification time (P < 0.0001).Conclusion: Femtosecond laser‐assisted cataract surgery appears to be as safe as conventional cataract surgery in the short term and results in significantly lower effective phacoemulsification time. Although it may allow for greater efficiency and decreased postoperative complications, further research is needed into long‐term safety aspects such as corneal endothelial cell loss.Keywords
This publication has 33 references indexed in Scilit:
- Macular morphology assessed by optical coherence tomography image segmentation after femtosecond laser–assisted and standard cataract surgeryJournal of Cataract & Refractive Surgery, 2012
- Early Experience with the Femtosecond Laser for Cataract SurgeryOphthalmology, 2012
- Intraocular Lens Tilt and Decentration Measured By Scheimpflug Camera Following Manual or Femtosecond Laser–created Continuous Circular CapsulotomyJournal of Refractive Surgery, 2012
- Femtosecond Laser Capsulotomy and Manual Continuous Curvilinear Capsulorrhexis Parameters and Their Effects on Intraocular Lens CentrationJournal of Refractive Surgery, 2011
- Comparison of Intraocular Lens Decentration Parameters After Femtosecond and Manual CapsulotomiesJournal of Refractive Surgery, 2011
- Femtosecond laser capsulotomyJournal of Cataract & Refractive Surgery, 2011
- Femtosecond Laser–Assisted Cataract Surgery with Integrated Optical Coherence TomographyScience Translational Medicine, 2010
- Complications of cataract surgeryClinical and Experimental Optometry, 2010
- Power modulations in new phacoemulsification technologyJournal of Cataract & Refractive Surgery, 2004
- Corneal refractive surgery with femtosecond lasersIEEE Journal of Selected Topics in Quantum Electronics, 1999