Custom Triflange Acetabular Components for Large Acetabular Defects: Minimum 10-Year Follow-up
Authors:
- K. David MooreKMK. David Moore
- Michelle D. McClennyMMMichelle D. McClenny
- Bradley W. WillsBWBradley W. Wills
- 1 May 2018
- journal article
- research article
- Published by SLACK, Inc. in Orthopedics
- Vol. 41 (3) , E316-E320
Abstract
Compromise of bony support presents a difficult problem in acetabular revision surgery. Although various methods have been proposed to cope with this problem, they have had variable results and little long-term follow-up. The authors reviewed the results of 37 patients undergoing custom triflange revision surgery. Two patients were lost to follow-up, leaving 35 patients with minimum 10-year clinical and radiographic follow-up. Thirty-two (91%) of 35 components were unrevised and functioning well at minimum 10-year follow-up. One component placed for pelvic discontinuity loosened at 12 years after surgery but was converted to a conventional total hip. One component had failure of 3 ischial screws at 6 months; however, at 11 years, the patient had no additional clinical or radiographic evidence of loosening. The average Harris hip score was 28 preoperatively and 90 postoperatively. Two components (6%) were removed for infection. There were no dislocations, fractures, or nerve injuries. Revision of large acetabular defects with a custom triflange component resulted in reliably good to excellent results at minimum 10-year follow-up. [ Orthopedics. 2018; 41(3):e316–e320.]Keywords
This publication has 21 references indexed in Scilit:
- Short-term Results of a Custom Triflange Acetabular Component for Massive Acetabular Bone Loss in Revision THAOrthopedics, 2013
- Pelvic Discontinuity Treated With Custom Triflange Component: A Reliable OptionClinical Orthopaedics and Related Research, 2012
- Acetabular revision using an anti-protrusion (ilio-ischial) cage and trabecular metal acetabular component for severe acetabular bone loss associated with pelvic discontinuityThe Journal of Bone and Joint Surgery. British volume, 2009
- Bridging Massive Acetabular Defects With the Triflange CupClinical Orthopaedics and Related Research, 2001
- Technical factors for success with metal ring acetabular reconstructionThe Journal of Arthroplasty, 2001
- Reconstruction of segmental defects during revision procedures of the acetabulum with the Burch-Schneider anti-protrusio cageThe Journal of Arthroplasty, 2001
- Reliability of acetabular bone defect classification systems in revision total hip arthroplastyThe Journal of Arthroplasty, 2001
- Revision total hip arthroplasty with the use of structural acetabular allograft and reconstruction ringThe Journal of Arthroplasty, 2000
- Acetabular revision with the Burch-Schnieder antiprotrusio cage and cancellous allograft boneThe Journal of Arthroplasty, 1995
- Midterm results (5.5–10 years) of acetabular allograft reconstruction with the acetabular reinforcement ring during total hip revisionThe Journal of Arthroplasty, 1994