Geometric evaluation and quantifying dosimetric impact of diverse deformable image registration algorithms on abdomen images with biomechanically modeled deformations
Open Access
- 11 September 2024
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (12) , e14511
Abstract
Purpose: Deformable image registration (DIR) has been increasingly used in radiation therapy (RT). The accuracy of DIR algorithms and how it impacts on the RT plan dosimetrically were examined in our study for abdominal sites using biomechanically modeled deformations.Methods: Five pancreatic cancer patients were enrolled in this study. Following the guidelines of AAPM TG‐132, a patient‐specific quality assurance (QA) workflow was developed to evaluate DIR for the abdomen using the TG‐132 recommended virtual simulation software ImSimQA (Shrewsbury, UK). First, the planning CT was deformed to simulate respiratory motion using the embedded biomechanical model in ImSimQA. Additionally, 5 mm translational motion was added to the stomach, duodenum, and small bowel. The original planning CT and the deformed CT were then imported into Eclipse and MIM to perform DIR. The output displacement vector fields (DVFs) were compared with the ground truth from ImSimQA. Furthermore, the original treatment plan was recalculated on the ground‐truth deformed CT and the deformed CT (with Eclipse and MIM DVF). The dose errors were calculated on a voxel‐to‐voxel basis.Results: Data analysis comparing DVF from Eclipse versus MIM show the average mean DVF magnitude errors of 2.8 ± 1.0 versus 1.1 ± 0.7 mm for stomach and duodenum, 5.2 ± 4.0 versus 2.5 ± 1.0 mm for small bowel, and 4.8 ± 4.1 versus 2.7 ± 1.1 mm for the gross tumor volume (GTV), respectively, across all patients. The mean dose error on stomach+duodenum and small bowel were 2.3 ± 0.6% for Eclipse, and 1.0 ± 0.3% for MIM. As the DIR magnitude error increases, the dose error range increase, for both Eclipse and MIM.Conclusion: In our study, an initial assessment was conducted to evaluate the accuracy of DIR and its dosimetric impact on radiotherapy. A patient‐specific DIR QA workflow was developed for pancreatic cancer patients. This workflow exhibits promising potential for future implementation as a clinical workflow.Keywords
This publication has 17 references indexed in Scilit:
- Deep‐learning‐based image registration and automatic segmentation of organs‐at‐risk in cone‐beam CT scans from high‐dose radiation treatment of pancreatic cancerMedical Physics, 2021
- Evaluation of a commercial deformable image registration algorithm for dual‐energy CT processingJournal of Applied Clinical Medical Physics, 2020
- End-to-end empirical validation of dose accumulation in MRI-guided adaptive radiotherapy for prostate cancer using an anthropomorphic deformable pelvis phantomRadiotherapy and Oncology, 2019
- Deformable image registration for radiation therapy: principle, methods, applications and evaluationActa Oncologica, 2019
- Practical quantification of image registration accuracy following the AAPM TG‐132 report frameworkJournal of Applied Clinical Medical Physics, 2018
- Effect of deformable registration on the dose calculated in radiation therapy planning CT scans of lung cancer patients a)Medical Physics, 2015
- Automatic detection system for multiple region of interest registration to account for posture changes in head and neck radiotherapyPhysics in Medicine & Biology, 2014
- A novel technique to enable experimental validation of deformable dose accumulationMedical Physics, 2012
- Semiautomated Motion Correction of Tumors in Lung CT-perfusion StudiesAcademic Radiology, 2011
- Comparison of 12 deformable registration strategies in adaptive radiation therapy for the treatment of head and neck tumorsRadiotherapy and Oncology, 2008