Impedance Threshold Device Combined With High-Quality Cardiopulmonary Resuscitation Improves Survival With Favorable Neurological Function After Witnessed Out-of-Hospital Cardiac Arrest
Open Access
- 1 January 2016
- journal article
- research article
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 80 (10) , 2124-2132
Abstract
The quality of cardiopulmonary resuscitation (CPR) has been recently shown to affect clinical outcome. The Resuscitation Outcomes Consortium (ROC) Prehospital Resuscitation Impedance Valve and Early Versus Delayed Analysis (PRIMED) trial showed no differences in outcomes with an active vs. sham impedance threshold device (ITD), a CPR adjunct that enhances circulation. It was hypothesized the active ITD would improve survival with favorable neurological outcomes in witnessed out-of-hospital cardiac arrest patients when used with high-quality CPR. Using the publicly accessible ROC PRIMED database, a post-hoc analysis was performed on all witnessed subjects with both compression rate and depth data (n=1,808) who received CPR within the study protocol definition of adequate CPR quality (compression rate 80-120/min and depth 4-6 cm; n=929). Demographics were similar between sham and active ITD groups. In witnessed subjects who received quality CPR, survival with favorable neurological function was 11.9% for the active ITD subjects (56/470) vs. 7.4% for the sham (34/459) (odds ratio 1.69 [95% confidence interval 1.08, 2.64]). There were no statistically significant differences for this primary outcome when CPR was performed outside the boundaries of the definition of adequate CPR quality. Multivariable models did not change these associations. An active ITD combined with adequate-quality conventional CPR has the potential to significantly improve survival after witnessed cardiac arrest. (Circ J 2016; 80: 2124-2132).Keywords
This publication has 39 references indexed in Scilit:
- Treatment of non-traumatic out-of-hospital cardiac arrest with active compression decompression cardiopulmonary resuscitation plus an impedance threshold deviceResuscitation, 2013
- Relationship Between Chest Compression Rates and Outcomes From Cardiac ArrestCirculation, 2012
- What is the role of chest compression depth during out-of-hospital cardiac arrest resuscitation?*Critical Care Medicine, 2012
- A Trial of an Impedance Threshold Device in Out-of-Hospital Cardiac ArrestNew England Journal of Medicine, 2011
- The prevalence of chest compression leaning during in-hospital cardiopulmonary resuscitationResuscitation, 2011
- Standard cardiopulmonary resuscitation versus active compression-decompression cardiopulmonary resuscitation with augmentation of negative intrathoracic pressure for out-of-hospital cardiac arrest: a randomised trialThe Lancet, 2011
- Leaning during chest compressions impairs cardiac output and left ventricular myocardial blood flow in piglet cardiac arrestCritical Care Medicine, 2010
- Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrestResuscitation, 2006
- Comparison of Standard Cardiopulmonary Resuscitation Versus the Combination of Active Compression-Decompression Cardiopulmonary Resuscitation and an Inspiratory Impedance Threshold Device for Out-of-Hospital Cardiac ArrestCirculation, 2003
- Prehospital cardiac arrest: The impact of witnessed collapse and bystander CPR in a metropolitan EMS system with short response timesAnnals of Emergency Medicine, 1990