A novel technique to quantify bone-to-implant contact of zygomatic implants: a radiographic analysis based on three-dimensional image registration and segmentation
Open Access
- 1 January 2023
- journal article
- research article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 52 (2) , 20220210
Abstract
Objectives: The purpose of this study is to establish a novel, reproducible technique to obtain the BIC area (BICA) between zygomatic implants and zygomatic bone based on post-operative cone-beam computed tomography (CBCT) images. Three-dimensional (3D) image registration and segmentation were used to eliminate the effect of metal-induced artifacts of zygomatic implants. Methods: An ex-vivo study was included to verify the feasibility of the new method. Then, the radiographic bone-to-implant contact (rBIC) of 143 implants was measured in a total of 50 patients. To obtain the BICA of zygomatic implants and the zygomatic bone, several steps were necessary, including image preprocessing of CBCT scans, identification of the position of zygomatic implants, registration, and segmentation of pre- and post-operative CBCT images, and 3D reconstruction of models. The conventional two-dimensional (2D) linear rBIC (rBICc) measurement method with post-operative CBCT images was chosen as a comparison. Results: The mean values of rBIC and rBICc were 15.08 ± 5.92 mm and 14.77 ± 5.14 mm, respectively. A statistically significant correlation was observed between rBIC and rBICc values ([ ]=0.86, p < 0.0001). Conclusions: This study proposed a standardized, repeatable, noninvasive technique to quantify the rBIC of post-operative zygomatic implants in 3D terms. This technique is comparable to conventional 2D linear measurements and seems to be more reliable than these conventional measurements; thus, this method could serve as a valuable tool in the performance of clinical research protocols.Keywords
This publication has 28 references indexed in Scilit:
- Zygomatic Implants Placed Using the Zygomatic Anatomy‐Guided Approach versus the Classical Technique: A Proposed System to Report Rhinosinusitis DiagnosisClinical Implant Dentistry and Related Research, 2013
- The Long‐Term Use of Zygomatic Implants: A 10‐Year Clinical and Radiographic ReportClinical Implant Dentistry and Related Research, 2012
- Peri-implant bone tissue assessment by comparing the outcome of intra-oral radiograph and cone beam computed tomography analyses to the histological standardClinical Oral Implants Research, 2010
- Determination of the length of zygomatic implants through computed tomography: establishing a protocolDentomaxillofacial Radiology, 2008
- Implants in Regenerated Bone in a Primate ModelJournal of Periodontology, 2001
- Radiographic and Digital Imaging in Periodontal PracticeJournal of Periodontology, 2000
- Understanding and controlling the bone–implant interfaceBiomaterials, 1999
- Clinical probing and radiographic assessment in relation to the histologic bone level at oral implants in monkeysClinical Oral Implants Research, 1997
- Marching cubes: A high resolution 3D surface construction algorithmACM SIGGRAPH Computer Graphics, 1987
- A method for the study of undecalcified bones and teeth with attached soft tissues*Journal of Oral Pathology & Medicine, 1982