Abstract
This article proposes a pulse laser ranging method based on the correlated sampling time expansion, which enhances the precision of pulse laser ranging. We introduced an additional sampling pulse signal, which has a certain frequency difference from the transmission signal. By utilizing the principle of correlation sampling, the sampling signal is used to sample the pulse echo signal, resulting in temporal expansion of the echo delay. The actual distance is then calculated based on the expansion factor. This method overcomes the limitations of traditional time-of-flight (TOF) methods that rely on time-to-digital converter (TDC) chip timing, substantially reducing timing errors. Our approach is implemented using a field-programmable gate array (FPGA), a sampling unit, and a set of laser transmission and reception devices, resulting in a low-cost system. Experimental results demonstrate that our method achieves high-precision ranging and effectively reduces errors in TOF ranging, with each measurement error reduced to the millimeter level or even lower. Our proposed method holds great promise in the field of high-precision ranging.
Funding Information
  • National Key Research and Development Program of China (2022YFB4500100)
  • Collaborative Innovation Platform Projects of Fuzhou
  • Xiamen and Quanzhou National Independent Innovation Demonstration Zone
  • National Natural Science Foundation of China (61836010)

This publication has 49 references indexed in Scilit: