Investigation on Pollution-Induced Flashovers of In-Service Insulators in Ethiopian Power Transmission Lines
Open Access
Abstract
Power transmission lines in Ethiopia are experiencing an alarmingly high frequency of unexplained outages triggered by environmental factors, which significantly undermine the reliability of the country’s power system. This paper presents investigations aiming to identify those among the unexplained fault records that have been caused by pollution induced flashovers. An identification method is developed, which associates the contextual fault features, such as information about the characteristics of the fault, fault location, and time of day, as well as month of its occurrence with local meteorological/climatic and environmental conditions. A total number of 4231 unexplained faults, recorded between 2015 and 2022, were analyzed. Among them, 1045 faults (24.7%) were identified as being most likely caused by pollution induced flashovers. The entire network suffered from more than 130 pollution-induced flashovers annually with a frequency of about 0.8 faults/100 km/year. The fault frequency strongly differed among the grid regions, being highest in the Northeast and lowest in the Southwest region. Moreover, the performed analyses also concentrated on the evaluation of the pollution performance of various insulator types employed in the network. The results indicate that porcelain insulators have the highest pollution-induced flashover intensity of 1.47 faults/year/1000 units, followed by silicone rubber polymeric composite insulators and glass insulators with the respective intensities of 1.21 and 0.83 faults/year/1000 units. These results indicate that despite the high expectations towards the pollution performance of silicone rubber polymeric insulators, their use in the Ethiopian climatic and environmental conditions appears to be unsatisfactory.Keywords
Funding Information
- Swedish International Development Cooperation Agency (Sida)—Ethiopia Bilateral Program (51080124)
This publication has 14 references indexed in Scilit:
- Analyses of unexplained faults in transmission lines in the power grid of EthiopiaElectric Power Systems Research, 2024
- Long-term management practices successfully reduce bird-related electrical faults in a transmission grid increasingly used by white storks for nestingJournal of Environmental Management, 2022
- Assessment of External Insulation Problems Related to Pollution and Climatic Conditions in EthiopiaIEEE Electrical Insulation Magazine, 2020
- Fault Statistics and Analysis of 220-kV and Above Transmission Lines in a Southern Coastal Provincial Power Grid of ChinaIEEE Open Access Journal of Power and Energy, 2020
- Characterisation of power system events on South African transmission power linesElectric Power Systems Research, 2012
- Failures in outdoor insulation caused by bird excrementElectric Power Systems Research, 2010
- Strategies for bating enviromental influences on overhead lines to improve quality of supply2006
- Recent changes in rainfall and rainy days in EthiopiaInternational Journal of Climatology, 2004
- Analysis of factors contributing to unexplained transmission line faults on a high voltage transmission network2003
- Bird streamer flashovers on FPL transmission linesIEEE Transactions on Power Delivery, 1995