Comprehensive morphomechanical analysis of brain aneurysms
- 3 January 2023
- journal article
- research article
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 165 (2) , 461-470
Abstract
Objective Brain aneurysms comprise different compartments that undergo unique biological processes. A detailed multimodal analysis incorporating 3D aneurysm wall enhancement (AWE), computational fluid dynamics (CFD), and finite element analysis (FEA) data can provide insights into the aneurysm wall biology. Methods Unruptured aneurysms were prospectively imaged with 7 T high-resolution MRI (HR-MRI). 3D AWE color maps of the entire aneurysm wall were generated and co-registered with contour plots of morphomechanical parameters derived from CFD and FEA. A multimodal analysis of the entire aneurysm was performed using 3D circumferential AWE (3D-CAWE), wall tension (WT), time-averaged wall shear stress (TAWSS), wall shear stress gradient (WSSG), and oscillatory shear index (OSI). A detailed compartmental analysis of each aneurysm’s dome, bleb, and neck was also performed. Results Twenty-six aneurysms were analyzed. 3D-CAWE + aneurysms had higher WT (p = 0.03) and higher TAWSS (p = 0.045) than 3D-CAWE- aneurysms. WT, TAWSS, and WSSG were lower in areas of focal AWE in the aneurysm dome compared to the neck (p = 0.009, p = 0.049, and p = 0.040, respectively), whereas OSI was higher in areas of focal AWE compared to the neck (p = 0.020). When compared to areas of no AWE of the aneurysm sac (AWE = 0.92 vs. 0.49, p = 0.001), blebs exhibited lower WT (1.6 vs. 2.45, p = 0.010), lower TAWSS (2.6 vs. 6.34), lower OSI (0.0007 vs. 0.0010), and lower WSSG (2900 vs. 5306). Fusiform aneurysms had a higher 3D-CAWE and WT than saccular aneurysms (p = 0.046 and p = 0.003, respectively). Conclusions Areas of focal high AWE in the sac and blebs are associated with low wall tension, low wall shear stress, and low flow conditions (TAWSS and WSSG). Conversely, the neck had average AWE, high wall tension, high wall shear stress, and high flow conditions. The aneurysm dome and the aneurysm neck have different morphomechanical environments, with increased mechanical load at the neck.Keywords
Funding Information
- NIH (1S10RR028821-01)
This publication has 41 references indexed in Scilit:
- On the prospect of patient-specific biomechanics without patient-specific properties of tissuesJournal of the Mechanical Behavior of Biomedical Materials, 2013
- High WSS or Low WSS? Complex Interactions of Hemodynamics with Intracranial Aneurysm Initiation, Growth, and Rupture: Toward a Unifying HypothesisAmerican Journal of Neuroradiology, 2013
- On the role of modeling choices in estimation of cerebral aneurysm wall tensionJournal of Biomechanics, 2012
- Saccular intracranial aneurysm: pathology and mechanismsActa Neuropathologica, 2012
- FEBio: Finite Elements for BiomechanicsJournal of Biomechanical Engineering, 2012
- An objective approach to digital removal of saccular aneurysms: technique and applicationsBritish Journal of Radiology, 2009
- Intracranial aneurysms: links among inflammation, hemodynamics and vascular remodelingNeurological Research, 2006
- Cellular Fluid Mechanics and MechanotransductionAnnals of Biomedical Engineering, 2005
- Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteriesPhysiological Measurement, 2005
- Multiaxial Mechanical Behavior of Human Saccular AneurysmsComputer Methods in Biomechanics and Biomedical Engineering, 2001