Apparent diffusion coefficient normalization of normal liver
Authors:
Open Access
- 1 January 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine
- Vol. 96 (3) , e5910
Abstract
Apparent diffusion coefficient (ADC) measurement in diffusion-weighted imaging (DWI) has been reported to be a helpful biomarker for detection and characterization of lesion. In view of the importance of ADC measurement reproducibility, the aim of this study was to probe the variability of the healthy hepatic ADC values measured at 3 MR scanners from different vendors and with different field strengths, and to investigate the reproducibility of normalized ADC (nADC) value with the spleen as the reference organ. Thirty enrolled healthy volunteers received DWI with GE 1.5T, Siemens 1.5T, and Philips 3.0T magnetic resonance (MR) systems on liver and spleen (session 1) and were imaged again after 10 to 14 days using only GE 1.5T MR and Philips 3.0T MR systems (session 2). Interscan agreement and reproducibility of ADC measurements of liver and the calculated nADC values (ADCliver/ADCspleen) were statistically evaluated between 2 sessions. In session 1, ADC and nADC values of liver were evaluated for the scanner-related variability by 2-way analysis of variance and intraclass correlation coefficients (ICCs). Coefficients of variation (CVs) of ADCs and nADCs of liver were calculated for both 1.5 and 3.0-T MR system. Interscan agreement and reproducibility of ADC measurements of liver and related nADCs between 2 sessions were found to be satisfactory with ICC values of 0.773 to 0.905. In session 1, the liver nADCs obtained from different scanners were consistent (P = 0.112) without any significant difference in multiple comparison (P = 0.117 to >0.99) by using 2-way analysis of variance with post-hoc analysis of Bonferroni method, although the liver ADCs varied significantly (P < 0.001). nADCs measured by 3 scanners were in good interscanner agreements with ICCs of 0.685 to 0.776. The mean CV of nADCs of both 1.5T MR scanners (9.6%) was similar to that of 3.0T MR scanner (8.9%). ADCs measured at 3 MR scanners with different field strengths and vendors could not be compared directly. Normalization of ADCs, however, may provide better reproducibility by overcoming these potential issues.Keywords
This publication has 35 references indexed in Scilit:
- Diffusion-weighted imaging of the liver: usefulness of ADC values in the differential diagnosis of focal lesions and effect of ROI methods on ADC measurementsMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- Diffusion‐weighted MRI of fatty liverJournal of Magnetic Resonance Imaging, 2011
- Diffusion‐weighted imaging of the abdomen at 3.0 Tesla: Image quality and apparent diffusion coefficient reproducibility compared with 1.5 TeslaJournal of Magnetic Resonance Imaging, 2010
- Field Strength and Diffusion Encoding Technique Affect the Apparent Diffusion Coefficient Measurements in Diffusion-Weighted Imaging of the AbdomenInvestigative Radiology, 2010
- Comparison between two-point and four-point methods for quantification of apparent diffusion coefficient of normal liver parenchyma and focal lesions. Value of normalization with spleenEuropean Journal of Radiology, 2010
- Effects of echo time on diffusion quantification of brain white matter at 1.5T and 3.0TMagnetic Resonance in Medicine, 2009
- Relative apparent diffusion coefficient: Determination of reference site and validation of benefit for detecting metastatic lymph nodes in uterine cervical cancerJournal of Magnetic Resonance Imaging, 2009
- Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free‐breathing diffusion‐weighted MR imaging of the liverJournal of Magnetic Resonance Imaging, 2008
- Relevance of b‐values in evaluating liver fibrosis: A study in healthy and cirrhotic subjects using two single‐shot spin‐echo echo‐planar diffusion‐weighted sequencesJournal of Magnetic Resonance Imaging, 2008
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986