Design and Construction of a Microcontroller-Based Ventilator Synchronized with Pulse Oximeter
Authors:
- 11 June 2016
- journal article
- systems level-quality-improvement
- Published by Springer Nature in Journal of Medical Systems
- Vol. 40 (7) , 1-10
Abstract
This study aims to introduce a novel device with which mechanical ventilator and pulse oximeter work in synchronization. Serial communication technique was used to enable communication between the pulse oximeter and the ventilator. The SpO2 value and the pulse rate read on the pulse oximeter were transmitted to the mechanical ventilator through transmitter (Tx) and receiver (Rx) lines. The fuzzy-logic-based software developed for the mechanical ventilator interprets these values and calculates the percentage of oxygen (FiO2) and Positive End-Expiratory Pressure (PEEP) to be delivered to the patient. The fuzzy-logic-based software was developed to check the changing medical states of patients and to produce new results (FiO2 ve PEEP) according to each new state. FiO2 and PEEP values delivered from the ventilator to the patient can be calculated in this way without requiring any arterial blood gas analysis. Our experiments and the feedbacks from physicians show that this device makes it possible to obtain more successful results when compared to the current practices.Keywords
This publication has 26 references indexed in Scilit:
- Intensive care clinicians’ opinion of conservative oxygen therapy (SpO2 90–92%) for mechanically ventilated patientsAustralian Critical Care, 2014
- Mechanical ventilation in the operating room: Adjusting VT, PEEP, and FiO2Trends in Anaesthesia and Critical Care, 2012
- SpO2 values in acute medical admissions breathing air—Implications for the British Thoracic Society guideline for emergency oxygen use in adult patients?Resuscitation, 2012
- A Low-cost Reader for Automatically Collecting Vital Signs in HospitalsJournal of Medical Systems, 2011
- Design and Realization of a Microcontroller Based E-Test Strip Application DeviceInstrumentation Science & Technology, 2009
- A Novel Fuzzy Logic Inference System for Decision Support in Weaning from Mechanical VentilationJournal of Medical Systems, 2009
- Basic Mechanical Ventilation2009
- Comparison of the Sp o 2 /F io 2 Ratio and the Pa o 2 /F io 2 Ratio in Patients With Acute Lung Injury or ARDSChest, 2007
- Signal processing methods for pulse oximetryComputers in Biology and Medicine, 1996
- Noninvasive Detection of Profound Arterial Desaturations Using a Pulse Oximetry DeviceAnesthesiology, 1985