Unmatched projector/backprojector pair for demultiplexing in multipinhole emission computed tomography
Authors:
- 1 December 2010
- journal article
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 49 (12) , 127004-9
Abstract
Statistically based iterative algorithms such as maximum likelihood-expectation maximization (ML-EM) are used for image reconstruction in single photon emission computed tomography (SPECT). Unmatched projector/backprojector pairs are sometimes used to accelerate the iteration process in the reconstruction algorithm. In this work, we propose and explore the use of an unmatched projector/backprojector pair for demultiplexing in multipinhole SPECT. Several simulations are conducted to evaluate the performance of the proposed method with uniform, hot-rod, and cold-rod phantoms. The proposed method incorporates an unmatched backprojector to utilize selective multiplexed projection data in reconstruction algorithms, while the projector is modeled as accurately as possible to represent realistic imaging geometry and the physical effects of multipinhole SPECT. The root mean square (rms) error and backprojection speed are evaluated to determine an unmatched backprojector. Our results demonstrate that the proposed method provides high-quality multipinhole SPECT images without multiplexing-related artifacts when a well-chosen unmatched backprojector is used.Keywords
Funding Information
- Ministry of Education, Science, and Technology (2010K001109)
This publication has 32 references indexed in Scilit:
- Comparison of Simultaneous Dual-Isotope Multipinhole SPECT with Rotational SPECT in a Group of Patients with Coronary Artery DiseaseJournal of Nuclear Medicine, 2008
- High-Resolution $^{125}$I Small Animal Imaging With a Coded Aperture and a Hybrid Pixel DetectorIEEE Transactions on Nuclear Science, 2008
- The pinhole: gateway to ultra-high-resolution three-dimensional radionuclide imagingEuropean Journal of Nuclear Medicine and Molecular Imaging, 2006
- Preliminary results from a Monte Carlo study of breast tumour imaging with low-energy high-resolution collimator and a modified uniformly-redundant array-coded apertureNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006
- Performance amelioration for small animal SPECT using optimized pinhole collimator and image correction techniqueIEEE Transactions on Nuclear Science, 2005
- Investigation of efficiency and spatial resolution using pinholes with small pinhole angleIEEE Transactions on Nuclear Science, 2003
- High-resolution SPECT using multipinhole collimationIEEE Transactions on Nuclear Science, 2003
- Optimization of pinhole collimator for small animal SPECT using Monte Carlo simulationIEEE Transactions on Nuclear Science, 2003
- A prototype coded aperture detector for small animal SPECTIEEE Transactions on Nuclear Science, 2002
- Analytic determination of pinhole collimator sensitivity with penetrationIEEE Transactions on Medical Imaging, 2001