Ultrasonic Fatigue Testing in the Tension-Compression Mode
- 7 March 2018
- journal article
- research article
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 133,p. e57007
Abstract
Ultrasonic fatigue testing is one of a few methods which allow investigating fatigue properties in the ultra-high cycle region. The method is based on exposing the specimen to longitudinal vibrations on its resonance frequency close to 20 kHz. With use of this method, it is possible to significantly decrease the time required for the test, when compared to conventional testing devices usually working at frequencies under 200 Hz. It is also used to simulate loading of material during operation in high speed conditions, such as those experienced by components of jet engines or car turbo pumps. It is necessary to operate only in the high and ultra-high cycle region, due to the possibility of extremely high deformation rates, which can have a significant influence on the test results. Specimen shape and dimensions have to be carefully selected and calculated to fulfill the resonance condition of the ultrasonic system; thus, it is not possible to test the full components or specimens of arbitrary shape. Before each test, it is necessary to harmonize the specimen with the frequency of the ultrasonic system to compensate for deviations of the real shape from the ideal one. It is not possible to run a test until a total fracture of the specimen, since the test is automatically terminated after initiation and propagation of the crack to a certain length, when the stiffness of the system changes enough to shift the system out of the resonance frequency. This manuscript describes the process of evaluation of materials' fatigue properties at high-frequency ultrasonic fatigue loading with use of mechanical resonance at a frequency close to 20 kHz. The protocol includes a detailed description of all steps required for a correct test, including specimen design, stress calculation, harmonizing with the resonance frequency, performing the test, and final static fracture.Keywords
This publication has 13 references indexed in Scilit:
- A new ultrasonic fatigue testing device for biaxial bending in the gigacycle regimeInternational Journal of Fatigue, 2017
- Influence of Severe Shot Peening on the Surface State and Ultra-High-Cycle Fatigue Behavior of an AW 7075 Aluminum AlloyJournal of Materials Engineering and Performance, 2017
- Investigation of the high and very high cycle fatigue behaviour of continuous fibre reinforced plastics by conventional and ultrasonic fatigue testingComposites Science and Technology, 2017
- Ultrasonic Fatigue Testing on the Polymeric Material PMMA, Used in Odontology ApplicationsProcedia Structural Integrity, 2017
- Cyclic torsion very high cycle fatigue of VDSiCr spring steel at different load ratiosInternational Journal of Fatigue, 2015
- Effect of severe shot peening on ultra-high-cycle fatigue of a low-alloy steelMaterials & Design (1980-2015), 2014
- Ultrasonic torsion and tension–compression fatigue testing: Measuring principles and investigations on 2024-T351 aluminium alloyInternational Journal of Fatigue, 2006
- Piezoelectric fatigue testing machines and devicesInternational Journal of Fatigue, 2006
- A new function for fatigue curves characterization and its multiple meritsInternational Journal of Fatigue, 2001
- Fracture mechanisms and fracture mechanics at ultrasonic frequenciesFatigue & Fracture of Engineering Materials & Structures, 1999