A test of comparative equilibration for determining non‐exchangeable stable hydrogen isotope values in complex organic materials
- 2 July 2009
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 23 (15) , 2316-2320
Abstract
Comparative equilibration has been proposed as a methodological approach for determining the hydrogen isotopic composition ( δ D) of non‐exchangeable hydrogen in complex organic materials, from feathers to blood and soils. This method depends on using homogenized standards that have been previously calibrated for their δ D values of non‐exchangeable H, that are compositionally similar to unknown samples, and that span an appropriate isotopic range. Currently no certified organic reference materials with exchangeable H exist, and so isotope laboratories have been required to develop provisional internal calibration standards, such as the keratin standards currently used in animal migration studies. Unfortunately, the isotope ratios of some samples fall outside the range of keratin standards currently used for comparative equilibration. Here we tested a set of five homogenized keratin powders as well as feathers from Painted Buntings and Dark‐eyed Juncos to determine the effects of extrapolating comparative equilibration normalization equations outside the isotopic range of keratin standards. We found that (1) comparative equilibration gave precise results within the range of the calibration standards; (2) linear extrapolation of normalization equations produced accurate δ D results to ∼40‰ outside the range of the keratins standards used (−187 to −108); and (3) for both homogenized keratin powders and heterogeneous unknown samples there was no difference in variance between samples within and outside the range of keratin standards. This suggested that comparative equilibration is a robust and practical method for determining the δ D of complex organic matrices, although caution is required for samples that fall far outside the calibration range. Copyright © 2009 John Wiley & Sons, Ltd.Keywords
Funding Information
- US National Science Foundation (0541740)
- US Environmental Protection Agency (R 833778)
This publication has 18 references indexed in Scilit:
- Evaluating uncertainty in the calculation of non‐exchangeable hydrogen fractions within organic materialsRapid Communications in Mass Spectrometry, 2009
- Simplified batch equilibration for D/H determination of non‐exchangeable hydrogen in solid organic materialRapid Communications in Mass Spectrometry, 2009
- SPATIAL AND TEMPORAL MIGRATION PATTERNS OF WILSON’S WARBLER (WILSONIA PUSILLA) IN THE SOUTHWEST AS REVEALED BY STABLE ISOTOPESOrnithology, 2007
- Stable‐hydrogen isotope heterogeneity in keratinous materials: mass spectrometry and migratory wildlife tissue subsampling strategiesRapid Communications in Mass Spectrometry, 2006
- A test of geographic assignment using isotope tracers in feathers of known originOecologia, 2005
- Global application of stable hydrogen and oxygen isotopes to wildlife forensicsOecologia, 2005
- Interpolating the isotopic composition of modern meteoric precipitationWater Resources Research, 2003
- Comparative equilibration and online technique for determination of non-exchangeable hydrogen of keratins for use in animal migration studiesIsotopes in Environmental and Health Studies, 2003
- Linking Breeding and Wintering Ranges of a Migratory Songbird Using Stable IsotopesScience, 2002
- Improved Method for Determining the Stable-Hydrogen Isotopic Composition (δD) of Complex Organic Materials of Environmental InterestEnvironmental Science & Technology, 2000