Metal-containing polystyrene beads as standards for mass cytometry
- 6 January 2010
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 25 (3) , 260-268
Abstract
We examine the suitability of metal-containing polystyrene beads for the calibration of a mass cytometer instrument, a single particle analyser based on an inductively coupled plasma ion source and a time of flight mass spectrometer. These metal-containing beads are also verified for their use as internal standards for this instrument. These beads were synthesized by multiple-stage dispersion polymerization with acrylic acid as a comonomer. Acrylic acid acts as a ligand to anchor the metal ions within the interior of the beads. Mass cytometry enabled the bead-by-bead measurement of the metal-content and determination of the metal-content distribution. Beads synthesized by dispersion polymerization that involved three stages were shown to have narrower bead-to-bead variation in their lanthanide content than beads synthesized by 2-stage dispersion polymerization. The beads exhibited insignificant release of their lanthanide content to aqueous solutions of different pHs over a period of six months. When mixed with KG1a or U937 cell lines, metal-containing polymer beads were shown not to affect the mass cytometry response to the metal content of element-tagged antibodies specifically attached to these cells.Keywords
This publication has 32 references indexed in Scilit:
- Bio-functional, lanthanide-labeled polymer particles by seeded emulsion polymerization and their characterization by novel ICP-MS detectionJournal of Analytical Atomic Spectrometry, 2009
- Lanthanide-Containing Polymer Microspheres by Multiple-Stage Dispersion Polymerization for Highly Multiplexed BioassaysJournal of the American Chemical Society, 2009
- Flow cytometry immunophenotyping for diagnosis of myelodysplastic syndromeHaematologica, 2009
- Study of Cell Antigens and Intracellular DNA by Identification of Element-Containing Labels and Metallointercalators Using Inductively Coupled Plasma Mass SpectrometryAnalytical Chemistry, 2008
- Development of analytical methods for multiplex bio-assay with inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 2008
- Toward quantitative fluorescence measurements with multicolor flow cytometryCytometry Part A, 2007
- Polymer‐Based Elemental Tags for Sensitive BioassaysAngewandte Chemie International Edition, 2007
- The development of quantum dot calibration beads and quantitative multicolor bioassays in flow cytometry and microscopyAnalytical Biochemistry, 2007
- Fluorescence Intensity Calibration for Immunophenotyping by Flow CytometryMethods, 2000
- Immunophenotyping of blood lymphocytes in childhoodReference values for lymphocyte subpopulationsThe Journal of Pediatrics, 1997