High-Intensity Focused Ultrasound for ex Vivo Kidney Tissue Ablation: Influence of Generator Power and Pulse Duration
Authors:
- 1 November 2004
- journal article
- research article
- Published by SAGE Publications in Journal of Endourology
- Vol. 18 (9) , 917-924
Abstract
Background and Purpose: The therapeutic application of noninvasive tissue ablation by high-intensity focused ultrasound (HIFU) requires precise physical definition of the focal size and determination of control parameters. The objective of this study was to measure the extent of ex-vivo porcine kidney tissue ablation at variable generator parameters and to identify parameters to control lesion size. Materials and Methods: The ultrasound waves generated by a cylindrical piezoceramic element (1.04 MHz) were focused at a depth of 100 mm using a parabolic reflector (diameter 100 mm). A needle hydrophone was used to measure the field distribution of the sound pressure. The morphology and extent of tissue necrosis were examined at generator powers of up to 400 W (Pel) and single pulse durations of as long as 8 seconds. Results: The two-dimensional field distribution resulted in an approximately ellipsoidal focus of 32 × 4 mm (–6 dB). A sharp demarcation between coagulation necrosis and intact tissue was observed. Lesion size was controlled by both the variation of generator power and the pulse duration. At a constant pulse duration of 2 seconds, a generator power of 100 W remained below the threshold doses for inducing a reproducible lesion. An increase in power to as high as 400 W induced lesions with average dimensions of as much as 11.2 × 3 mm. At constant total energy (generator power × pulse duration), lesion size increased at higher generator power. Conclusions: This ultrasound generator can induce defined and reproducible necrosis in ex-vivo kidney tissue. Lesion size can be controlled by adjusting the generator power and pulse duration. Generator power, in particular, turned out to be a suitable control parameter for obtaining a lesion of a defined size.Keywords
This publication has 16 references indexed in Scilit:
- Technical characterization of an ultrasound source for noninvasive thermoablation by high‐intensity focused ultrasoundBJU International, 2002
- High Intensity Focused Ultrasound as Noninvasive Therapy for Multilocal Renal Cell Carcinoma: Case Study and Review of The LiteratureJournal of Urology, 2002
- Results and Side Effects of High-Intensity Focused Ultrasound in Localized Prostate CancerJournal of Endourology, 2001
- Incidental renal cell carcinoma—age and stage characterization and clinical implications: study of 1092 patients (1982–1997)Urology, 2000
- Focused Extracorporeal PyrotherapyEuropean Urology, 1993
- Tissue Destruction with Focused Ultrasound in vivoEuropean Urology, 1993
- Intense Focused Ultrasound in MedicineEuropean Urology, 1993
- Focused Extracorporeal Pyrotherapy: Feasibility Study in ManJournal of Endourology, 1992
- Fundamental Neurological Research and Human Neurosurgery Using Intense UltrasoundIRE Transactions on Medical Electronics, 1960
- Production of Focal Destructive Lesions in the Central Nervous System With UltrasoundJournal of Neurosurgery, 1954