Contribution of reference electrode to the compound muscle action potential
- 23 April 2007
- journal article
- research article
- Published by Wiley in Muscle & Nerve
- Vol. 36 (1) , 87-92
Abstract
In compound muscle action potential (CMAP) recording, the contribution by the reference electrode is considered to be much smaller than that of the active electrode. We tested this assumption by making quantitative measurements of the signals recorded individually by the active and reference electrodes. In the thenar (median nerve) and extensor digitorum brevis (peroneal nerve) muscles, the reference electrode did contribute less. In the hypothenar muscle (ulnar nerve), however, the signals recorded by active and reference electrodes were of similar amplitude. In tibial nerve conduction studies (NCS), the CMAP from the abductor hallucis (AH) muscle was recorded mainly by the reference electrode; the large‐amplitude signal recorded by the reference electrode is attributed to volume‐conducted activity from other muscles stimulated during the study. The onset latency of the potential recorded by the active and reference electrodes was similar despite significantly different distances from the stimulating site. Hence, the merits of using anatomic landmarks for defining the distal stimulation site are assessed. When the reference electrode makes a large contribution, the CMAP amplitude may not decrease commensurate with any wasting of the muscle under the active recording electrode, and the need to use another muscle for recording the CMAP for that nerve should be considered. Muscle Nerve, 2007Keywords
This publication has 10 references indexed in Scilit:
- Optimal recording electrode placement in the lumbrical–interossei comparison studyMuscle & Nerve, 2006
- CMAP amplitude cartography of muscles innervated by the median, ulnar, peroneal, and tibial nervesMuscle & Nerve, 1999
- The influence of active electrode placement on CMAP amplitudeElectroencephalography and Clinical Neurophysiology/Electromyography and Motor Control, 1997
- The influence of the reference electrode on CMAP configuration: Leg nerve observations and an alternative reference siteMuscle & Nerve, 1996
- Motor Nerve Conduction StudiesJournal Of Clinical Neurophysiology, 1995
- Influence of recording site on CMAP amplitude and on its variation over a length of nerveMuscle & Nerve, 1994
- Recording characteristics of the surface EMG electrodesMuscle & Nerve, 1994
- The influence of the reference electrode on CMAP configurationMuscle & Nerve, 1993
- Far‐field potentials in muscleMuscle & Nerve, 1991
- Electrophysiological estimation of the number of motor units within a human muscleJournal of Neurology, Neurosurgery & Psychiatry, 1971