Morphologic compatibility of intraocular lens haptics and the lens capsule
Authors:
- Goro EguchiGEGoro Eguchi
- 1 October 1997
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 23 (8) , 1254-1259
Abstract
To evaluate the mechanical relationship between the intraocular lens (IOL) haptic and the capsular bag by quantitatively analyzing the fit of the haptic with the capsule equator and the capsular bag deformity induced by the implanted lens haptics. Division of Morphogenesis, Department of Developmental Biology, National Institute for Basic Biology, Okazaki, Japan. Following implantation of a poly(methyl methacrylate)(PMMA) ring in three excised human capsular bags with continuous curvilinear capsulorhexis (CCC), IOLs with different overall lengths or haptic designs were implanted in the bags and photographed. The straight length of the area of contact between the haptic and the capsule equator on the photographs was measured to provide a quantitative index of in-the-bag fixation and the length from the external margin of the PMMA ring to the external margin of the loop along the maximal diameter of the capsular bag, to indicate the quantitative degree of capsular deformity induced by an IOL. An IOL with modified-C loops produced better fit along the capsule equator and less deformity than an IOL with modified-J loops, and an IOL with an overall length of 12.0 or 12.5 mm produced a sufficiently good fit and less distortion of the capsular bag than an IOL with an overall length over 13.0 mm. An IOL with modified-C loops and an overall length of 12.0 or 12.5 mm is adequate for in-the-bag implantation following CCC.Keywords
This publication has 10 references indexed in Scilit:
- Side-View Analysis of the LensArchives of Ophthalmology (1950), 2011
- The Capsular Bag after Short- and Long-term Fixation of Intraocular LensesOphthalmology, 1995
- Practice styles and preferences of ASCRS members—1994 surveyJournal of Cataract & Refractive Surgery, 1995
- Decentration associated with asymmetric capsular shrinkage and intraocular lens design in a rabbit modelJournal of Cataract & Refractive Surgery, 1995
- Long-term decentration of intraocular lenses implanted with envelope capsulotomy and continuous curvilinear capsulotomy: A comparative studyJournal of Cataract & Refractive Surgery, 1995
- A ring to support the capsular bag after continuous curvilinear capsulorhexisJournal of Cataract & Refractive Surgery, 1994
- Comparison of shape recovery ratios in various intraocular lens hapticsJournal of Cataract & Refractive Surgery, 1992
- Loop memory of posterior chamber intraocular lenses of various sizes, designs, and loop materialsJournal of Cataract & Refractive Surgery, 1992
- Preparation and Study of Human Eyes Obtained Postmortem with the Miyake Posterior Photographic TechniqueOphthalmology, 1990
- PRESBYOPIABritish Journal of Ophthalmology, 1962