Engineering strategies towards overcoming bleeding and glial scar formation around neural probes
Open Access
- 14 January 2022
- journal article
- review article
- Published by Springer Nature in Cell and tissue research
- Vol. 387 (3) , 461-477
Abstract
Neural probes are sophisticated electrophysiological tools used for intra-cortical recording and stimulation. These microelectrode arrays, designed to penetrate and interface the brain from within, contribute at the forefront of basic and clinical neuroscience. However, one of the challenges and currently most significant limitations is their ‘seamless’ long-term integration into the surrounding brain tissue. Following implantation, which is typically accompanied by bleeding, the tissue responds with a scarring process, resulting in a gliotic region closest to the probe. This glial scarring is often associated with neuroinflammation, neurodegeneration, and a leaky blood–brain interface (BBI). The engineering progress on minimizing this reaction in the form of improved materials, microfabrication, and surgical techniques is summarized in this review. As research over the past decade has progressed towards a more detailed understanding of the nature of this biological response, it is time to pose the question: Are penetrating probes completely free from glial scarring at all possible?Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (EXC 1086)
- Federal Ministry of Economics, Science and Arts of Baden-Württemberg
- National Institute of Health USA (R01NS109498)
- Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg
- H2020 European Research Council (759655, 759655, 899287)
- Albert-Ludwigs-Universität Freiburg im Breisgau
This publication has 139 references indexed in Scilit:
- Brain–machine interface: closer to therapeutic reality?The Lancet, 2013
- Ancrod and Fibrin FormationStroke, 2011
- Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodiesJournal of Neural Engineering, 2011
- Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex usingin vivotwo-photon mappingJournal of Neural Engineering, 2010
- Fibrinogen Triggers Astrocyte Scar Formation by Promoting the Availability of Active TGF-β after Vascular DamageThe Journal of Neuroscience, 2010
- Insertion shuttle with carboxyl terminated self-assembled monolayer coatings for implanting flexible polymer neural probes in the brainJournal of Neuroscience Methods, 2009
- In VivoPenetration Mechanics and Mechanical Properties of Mouse Brain Tissue at Micrometer ScalesIEEE Transactions on Biomedical Engineering, 2008
- Complex impedance spectroscopy for monitoring tissue responses to inserted neural implantsJournal of Neural Engineering, 2007
- Parylene flexible neural probes integrated with microfluidic channelsLab on a Chip, 2005
- Large-scale recording of neuronal ensemblesNature Neuroscience, 2004