Anemia is an important public health problem, and accurate estimates may inform policy and programs. Although hemoglobin assessment of venous blood via automated hematology analyzers (AHA) is recommended, most population-based surveys are based on analysis of capillary blood via portable hemoglobinometers to estimate anemia prevalence. To evaluate screening methods for hemoglobin and anemia assessment using paired venous samples. Participants were women of reproductive age (15-40y) who were not pregnant or lactating. Paired venous whole blood samples (n = 896) were analyzed for hemoglobin (Hb) via portable hemoglobinometer (HemoCue 301) and Coulter Counter AHA. Anemia and severe anemia were defined as Hb via HemoCue vs. AHA (36.3% vs. 41.6%; p-value 35%: 62.7% vs. ≤35%: 80.1), or whole-body fat (WBF >35%: 63.9% vs. ≤35%: 80.3%). Findings suggest that women with anemia may be incorrectly identified as not anemic via portable hemoglobinometer, and the anemia prevalence may be underestimated at the population level. Registration number: NCT04048330.Keywords
Funding Information
- CDC
- Cornell University
- University of South Carolina
- DRDC (5U01DD001007)
- NICHD (T32 HD087137)
- NIDDK (T32 DK007158)
This publication has 67 references indexed in Scilit:
- Biomarkers of vitamin B-12 status in NHANES: a roundtable summaryThe American Journal of Clinical Nutrition, 2011
- Comparison of Serum and Red Blood Cell Folate Microbiologic Assays for National Population SurveysThe Journal of Nutrition, 2011
- Hemoglobin estimation by the HemoCue® portable hemoglobin photometer in a resource poor settingBMC Clinical Pathology, 2011
- Comparison of the Analytic Performance Between the B-HB and HB-201+ HemoCue® Hemoglobinometers for Venous and Capillary Blood Under Field Work ConditionsEcology of Food and Nutrition, 2008
- C-Reactive Protein, Inflammatory Conditions, and Cardiovascular Disease RiskThe American Journal of Medicine, 2007
- Evaluation of an automated soluble transferrin receptor (sTfR) assay on the Roche Hitachi analyzer and its comparison to two ELISA assaysClinica Chimica Acta, 2007
- Evaluation of the utility of the HemoCue 301 haemoglobinometer for blood donor screeningVox Sanguinis, 2007
- Utility of point-of-care haemoglobin measurement in the HemoCue-B haemoglobin for the initial diagnosis of anaemiaClinical and Laboratory Haematology, 2005
- Maternal anaemia and its impact on perinatal outcomeTropical Medicine & International Health, 2004
- The quantitative assessment of body ironBlood, 2003