A 32 x 32 capacitive micromachined ultrasonic transducer array manufactured in standard CMOS
- 7 August 2012
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 59 (7) , 1521-1536
Abstract
As ultrasound imagers become increasingly portable and lower cost, breakthroughs in transducer technology will be needed to provide high-resolution, real-time 3-D imaging while maintaining the affordability needed for portable systems. This paper presents a 32 × 32 ultrasound array prototype, manufactured using a CMUT-in-CMOS approach whereby ultrasonic transducer elements and readout circuits are integrated on a single chip using a standard integrated circuit manufacturing process in a commercial CMOS foundry. Only blanket wet-etch and sealing steps are added to complete the MEMS devices after the CMOS process. This process typically yields better than 99% working elements per array, with less than ±1.5 dB variation in receive sensitivity among the 1024 individually addressable elements. The CMUT pulseecho frequency response is typically centered at 2.1 MHz with a -6 dB fractional bandwidth of 60%, and elements are arranged on a 250 μm hexagonal grid (less than half-wavelength pitch). Multiplexers and CMOS buffers within the array are used to make on-chip routing manageable, reduce the number of physical output leads, and drive the transducer cable. The array has been interfaced to a commercial imager as well as a set of custom transmit and receive electronics, and volumetric images of nylon fishing line targets have been produced.Keywords
This publication has 37 references indexed in Scilit:
- Design of a high-voltage analog front-end circuit for integration with CMUT arrays2010
- Multi-row linear cMUT array using cMUTs and multiplexing electronics2009
- Front-end CMOS electronics for monolithic integration with CMUT arrays: Circuit design and initial experimental results2008
- Optimization of sparse synthetic transmit aperture imaging with coded excitation and frequency divisionUltrasonics, 2005
- Microfabricated ultrasonic transducers monolithically integrated with high voltage electronics2005
- Residual stress in thin-film parylene-c2003
- Multielement synthetic transmit aperture imaging using temporal encodingIEEE Transactions on Medical Imaging, 2003
- A High-Density Flexible Connector Array for Multi-Substrate Packages2003
- Surface micromachined capacitive ultrasonic transducersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1998
- Synthetic aperture imaging for small scale systemsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1995