The impact of pediatric-specific dose modulation curves on radiation dose and image quality in head computed tomography
- 5 August 2015
- journal article
- Published by Springer Nature in Pediatric Radiology
- Vol. 45 (12) , 1814-1822
Abstract
The volume of CT examinations has increased with resultant increases in collective dose values over the last decade. To analyze the impact of the tube current and voltage modulation for dose values and image quality of pediatric head CT examinations. Head CT examinations were performed on anthropomorphic phantoms and four pediatric age categories before and after the introduction of dedicated pediatric curves for tube voltage and current modulation. Local diagnostic reference levels were calculated. Visual grading characteristic image quality evaluation was performed by four pediatric neuroradiologists and image noise comparisons were performed. Pediatric-specific modulation curves demonstrated a 49% decrease in mean radiation dose for phantom examinations. The local diagnostic reference levels (CTDIvol) for clinical examinations decreased by 52%, 41%, 46% and 40% for newborn, 5-, 10- and 15-year-old patients, respectively. Visual grading characteristic image quality was maintained for the majority of age categorizations (area under the curve = 0.5) and image noise measurements did not change (P = 0.693). Pediatric-specific dose modulation curves resulted in an overall mean dose reduction of 45% with no significant differences in subjective or objective image quality findings.Keywords
This publication has 27 references indexed in Scilit:
- Effect of Low Tube Voltage on Image Quality, Radiation Dose, and Low-Contrast Detectability at Abdominal Multidetector CT: Phantom StudyJournal of Biomedicine and Biotechnology, 2012
- Pointers for Optimizing Radiation Dose in Pediatric CT ProtocolsJournal of the American College of Radiology, 2012
- Experimental Study and Optimization of Scan Parameters That Influence Radiation Dose in Temporal Bone High-Resolution Multidetector Row CTAmerican Journal of Neuroradiology, 2011
- Survey of practice in paediatric computed tomographyRadiation Protection Dosimetry, 2011
- A method to analyse observer disagreement in visual grading studies: example of assessed image quality in paediatric cerebral multidetector CT imagesBritish Journal of Radiology, 2010
- VIEWDEX: an efficient and easy-to-use software for observer performance studiesRadiation Protection Dosimetry, 2010
- Simulated dose reduction by adding artificial noise to measured raw data: a validation studyRadiation Protection Dosimetry, 2010
- Radiation dose evaluation in 64-slice CT examinations with adult and paediatric anthropomorphic phantomsBritish Journal of Radiology, 2009
- Pediatric Chest MDCT Using Tube Current Modulation: Effect on Radiation Dose with Breast ShieldingAmerican Journal of Roentgenology, 2008
- Visual grading characteristics (VGC) analysis: a non-parametric rank-invariant statistical method for image quality evaluationBritish Journal of Radiology, 2007