Engineers use double-skin façades (DSF) to lower the energy consumption of buildings as they can potentially control incoming wind speeds and the amount of solar heat gain. The purpose of this present study was to (1) evaluate the use of DSFs, (2) its efficacy in improving the energy performance of high-rise office buildings in the hot, dry summer climate of the Mediterranean, and (3) to develop an optimum DSF model for this climate based on industry standards and recommendations for high-performance DSF parameters. In order to determine the efficiency of DSFs, two distinct variables, building orientation and the number of DSFs used, were taken into consideration. This study adopted an experimental (generate and test) research design and used Autodesk® Ecotect® Analysis software to develop computer simulations with which to assess 15 single façades, juxtaposed façades, three façades, and four façades on cardinal orientations. The recorded energy consumption and savings were then compared with that of the reference model. The results indicated that the three DSF model, i.e., the S14 model, reduced energy consumption during heating by 28% and by 53.5% when cooling a high-rise office building located in the hot, dry summer climate of the Mediterranean (Csa).Keywords
Funding Information
- Scientific Research Deanship at University of Ha’il—Saudi Arabia (RG-21 029)
This publication has 36 references indexed in Scilit:
- Impact of perforated solar screens on daylight availability and low energy use in officesAdvances in Building Energy Research, 2018
- Perspectives of double skin façades for naturally ventilated buildings: A reviewRenewable and Sustainable Energy Reviews, 2014
- A review of sensitivity analysis methods in building energy analysisRenewable and Sustainable Energy Reviews, 2013
- Will multi-facade systems reduce cooling energy in fully glazed buildings? A scoping study of UAE buildingsEnergy and Buildings, 2013
- Investigation on energy performance of double skin façade in Hong KongEnergy and Buildings, 2009
- A CFD approach to evaluate the influence of construction and operation parameters on the performance of Active Transparent Façades in Mediterranean climatesEnergy and Buildings, 2009
- An investigation of the potential for natural ventilation and building orientation to achieve thermal comfort in warm and humid climatesSolar Energy, 2009
- Numerical investigation on thermal performance and correlations of double skin façade with buoyancy-driven airflowEnergy and Buildings, 2008
- The most efficient position of shading devices in a double-skin facadeEnergy and Buildings, 2007
- World Map of the Köppen-Geiger climate classification updatedMeteorologische Zeitschrift, 2006