Argon plasma coagulation in the right and left colon: safety–risk profile of the 60W–1.2 l/min setting
Authors:
- 20 March 2014
- journal article
- research article
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 49 (5) , 632-641
Abstract
Background and study aim. The 40W–0.8 l/min setting is widely recommended for argon plasma coagulation (APC) in the right colon. Until March 2012, we used the 60W–1.2 l/min setting for all sites of the colon. By auditing our experience, we assessed the safety–risk profile of the 60W–1.2 l/min setting in the right and left colon. Patients and methods. All cases treated with APC by a single endoscopist, using the 60W–1.2 l/min setting for all sites of the colon between October 2001 and December 2007 were identified retrospectively and site, type, number of lesions, and complications were recorded. Between January 2008 and March 2012, information was recorded prospectively. Results. In the retrospective audit, 290 lesions (101 cecum/ascending, 120 sigmoid/descending, 69 transverse) were treated in 241 patient endoscopies. There were no perforations. In the prospective audit, 156 lesions (83 cecum/ascending, 47 sigmoid/descending, 26 transverse) were treated in 132 patient endoscopies. There was 1/83 (1.2%) perforation in the cecum/ascending colon and none in the transverse or sigmoid/descending (n.s.). Combined, the results yield a cecal/ascending perforation rate of 1/153 (0.6%) patient endoscopies, 1/184 (0.5%) lesions treated and overall perforation rate for all sites of the colon of 1/373 (0.3%) patient endoscopies and 1/446 (0.2%) lesions. Post-polypectomy syndrome and delayed bleeding each occurred in 3/373 (0.8%) patient endoscopies and 3/446 (0.7%) lesions. There were no deaths. Conclusion. In the cecum and ascending colon, the APC perforation rate at the 60W–1.2 l/min setting was no higher than in the left colon and is similar to that reported in previously published series. Therefore, it appears safe, provided the precautions we describe are strictly followed.Keywords
This publication has 23 references indexed in Scilit:
- Colonoscopy‐associated perforation: a 7‐year survey of in‐hospital frequency, treatment and outcome in a German university hospitalColorectal Disease, 2012
- Long-Term Outcome of Argon Plasma Ablation Therapy for Bleeding in 100 Consecutive Patients with Colonic AngiodysplasiaDiseases of the Colon & Rectum, 2006
- A novel method of treating colonic angiodysplasiaGastrointestinal Endoscopy, 2006
- Argon plasma coagulation in the treatment of hemorrhagic radiation proctitis is efficient but requires a perfect colonic cleansing to be safeEuropean Journal of Gastroenterology & Hepatology, 2004
- Colonic Perforations after Gas Explosion Induced by Argon Plasma CoagulationEndoscopy, 2004
- Argon Plasma Coagulation after Piecemeal Polypectomy of Sessile Colorectal Adenomas: Long-Term Follow-Up StudyEndoscopy, 2003
- Argon Plasma Coagulation for the Treatment of Hemorrhagic Radiation ProctitisEndoscopy, 2000
- Treatment of Radiation Proctitis with Argon Plasma CoagulationEndoscopy, 2000
- Argonplasmakoagulation in der flexiblen Endoskopie*: Bewertung eines neuen therapeutischen Verfahrens nach 1606 AnwendungenDMW - Deutsche Medizinische Wochenschrift, 1997
- Argon Plasma Coagulation in Flexible Gastrointestinal Endoscopy: Pilot ExperiencesEndoscopy, 1997