Fault diagnosis in a five-level multilevel inverter using an artificial neural network approach
Open Access
- 4 January 2023
- journal article
- research article
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 1,p. 31-39
Abstract
Introduction. Cascaded H-bridge multilevel inverters (CHB-MLI) are becoming increasingly used in applications such as distribution systems, electrical traction systems, high voltage direct conversion systems, and many others. Despite the fact that multilevel inverters contain a large number of control switches, detecting a malfunction takes a significant amount of time. In the fault switch configurations diode included for freewheeling operation during open-fault condition. During short circuit fault conditions are carried out by the fuse, which can reveal the freewheeling current direction. The fault category can be identified independently and also failure of power switches harmed by the functioning and reliability of CHB-MLI. This paper investigates the effects and performance of open and short switching faults of multilevel inverters. Output voltage characteristics of 5 level MLI are frequently determined from distinctive switch faults with modulation index value of 0.85 is used during simulation analysis. In the simulation experiment for the modulation index value of 0.85, one second open and short circuit faults are created for the place of faulty switch. Fault is identified automatically by means of artificial neural network (ANN) technique using sinusoidal pulse width modulation based on distorted total harmonic distortion (THD) and managed by its own. The novelty of the proposed work consists of a fast Fourier transform (FFT) and ANN to identify faulty switch. Purpose. The proposed architecture is to identify faulty switch during open and short failures, which has to be reduced THD and make the system in reliable operation. Methods. The proposed topology is to be design and evaluate using MATLAB/Simulink platform. Results. Using the FFT and ANN approaches, the normal and faulty conditions of the MLI are explored, and the faulty switch is detected based on voltage changing patterns in the output. Practical value. The proposed topology has been very supportive for implementing non-conventional energy sources based multilevel inverter, which is connected to large demand in grid.Keywords
This publication has 22 references indexed in Scilit:
- Design and Implementation of Universal Converter Conception et implémentation d’un convertisseur universelIEEE Canadian Journal of Electrical and Computer Engineering, 2022
- A Modified Multi Level Inverter With Inverted SPWM ControlIEEE Canadian Journal of Electrical and Computer Engineering, 2022
- A novel dual-leg DC-DC converter for wide range DC-AC conversionAutomatika, 2022
- A Single-Carrier-Based Pulse-Width Modulation Template for Cascaded H-Bridge Multilevel InvertersIEEE Access, 2021
- A Fault-Tolerant Five-Level Inverter Topology With Reduced Component Count for OEIM DrivesIEEE Journal of Emerging and Selected Topics in Power Electronics, 2020
- A Generalized Switch Fault Diagnosis for Cascaded H-Bridge Multilevel Inverters Using Mean Voltage PredictionIEEE Transactions on Industry Applications, 2019
- A New Fault-Tolerant Control Method for Cascaded H-Bridge Multilevel Inverter to Increase Maximum Output Voltage2019
- Fault Tolerance and Energy Sharing Analysis of a Single Phase Multilevel Inverter Topology2018
- A Fault-Diagnosis and Fault-Tolerant Control Scheme for Flying Capacitor Multilevel InvertersIEEE Transactions on Industrial Electronics, 2016
- A Single-Phase Cascaded Multilevel Inverter Based on a New Basic Unit With Reduced Number of Power SwitchesIEEE Transactions on Industrial Electronics, 2014