Measurement of anode surface temperature during a high-current vacuum arc
Author:
- 1 November 1975
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 46 (11) , 4701-4704
Abstract
Anode surface temperature was measured during a 3.8-kA-peak-current 7.2-ms-duration discharge between 2.5-cm-diam Ni electrodes spaced 9 mm apart. The temperature was determined by measurements of the spectral radiance of the anode in the 0.6–1.0-μm spectral region by means of a Si photovoltaic detector and narrow-band interference filters. The spectral radiance was related to anode surface temperature through the Planck radiation law. The major uncertainty in the measurement was the uncertainty of the emissivity. The actual temperature could be bracketed, however, by assuming alternatively the lowest published emissivity and unity emissivity. Prior to high-voltage arcing onset at 2.7 kA, the anode surface temperature was below 1500 °K. After high-voltage arcing onset the surface temperature rose very rapidly, reaching an equilibrium temperature of approximately 2900 °K.Keywords
This publication has 8 references indexed in Scilit:
- Interferometric measurement of electron and vapor densities in a high-current vacuum arcJournal of Applied Physics, 1974
- Anode surface radiance from microsecond vacuum arcsJournal of Applied Physics, 1974
- Anode Spot Instability I. The Homogeneous Short Gap InstabilityIEEE Transactions on Plasma Science, 1974
- Anode Phenomena in Metal-Vapor Arcs at High CurrentsJournal of Applied Physics, 1971
- High-current vacuum arcs. Part 1: An experimental studyProceedings of the Institution of Electrical Engineers, 1970
- Anode Voltage Drop and Anode Spot Formation in dc Vacuum ArcsJournal of Applied Physics, 1969
- Triggered vacuum gapsProceedings of the IEEE, 1966
- Analysis of Electrode Phenomena in the High-Current ArcJournal of Applied Physics, 1955