Modular Coils with Low Hydrogen Content Especially for MRI of Dry Solids
Open Access
- 23 October 2015
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (10) , e0139763
Abstract
Recent advances have enabled fast magnetic resonance imaging (MRI) of solid materials. This development has opened up new applications for MRI, but, at the same time, uncovered new challenges. Previously, MRI-invisible materials like the housing of MRI detection coils are now readily depicted and either cause artifacts or lead to a decreased image resolution. In this contribution, we present versatile, multi-nuclear single and dual-tune MRI coils that stand out by (1) a low hydrogen content for high-resolution MRI of dry solids without artifacts; (2) a modular approach with exchangeable inductors of variable volumes to optimally enclose the given object; (3) low cost and low manufacturing effort that is associated with the modular approach; (4) accurate sample placement in the coil outside of the bore, and (5) a wide, single- or dual-tune frequency range that covers several nuclei and enables multinuclear MRI without moving the sample. The inductors of the coils were constructed from self-supporting copper sheets to avoid all plastic materials within or around the resonator. The components that were mounted at a distance from the inductor, including the circuit board, coaxial cable and holder were manufactured from polytetrafluoroethylene. Residual hydrogen signal was sufficiently well suppressed to allow 1H-MRI of dry solids with a minimum field of view that was smaller than the sensitive volume of the coil. The SNR was found to be comparable but somewhat lower with respect to commercial, proton-rich quadrature coils, and higher with respect to a linearly-polarized commercial coil. The potential of the setup presented was exemplified by 1H / 23Na high-resolution zero echo time (ZTE) MRI of a model solution and a dried human molar at 9.4 T. A full 3D image dataset of the tooth was obtained, rich in contrast and similar to the resolution of standard cone-beam computed tomography.Keywords
This publication has 15 references indexed in Scilit:
- Ultrashort echo time (UTE) MRI for the assessment of caries lesionsDentomaxillofacial Radiology, 2013
- Dental MRI: Imaging of soft and solid components without ionizing radiationJournal of Magnetic Resonance Imaging, 2012
- MRI with Zero Echo Time2012
- Capturing Signals from Fast-relaxing Spins with Frequency-Swept MRI: SWIFT2012
- High‐resolution ZTE imaging of human teethNMR in Biomedicine, 2012
- MRI with zero echo time: Hard versus sweep pulse excitationMagnetic Resonance in Medicine, 2011
- RF coil considerations for short‐T2 MRIMagnetic Resonance in Medicine, 2010
- Magnetic resonance imaging performed on a hydrated mummy of medieval KoreaJournal of Anatomy, 2010
- Sensitivity and Resolution of Constant-Time ImagingJournal of Magnetic Resonance, Series B, 1994
- High resolution NMR imaging in solidsPhysica B+C, 1985