Heating induced near deep brain stimulation lead electrodes during magnetic resonance imaging with a 3 T transceive volume head coil
Authors:
- Devashish ShrivastavaDSDevashish Shrivastava
- Aviva AboschAAAviva Abosch
- John HughesJHJohn Hughes
- Ute GoerkeUGUte Goerke
- Lance DelaBarreLDLance DelaBarre
- Rachana VisariaRVRachana Visaria
- Noam HarelNHNoam Harel
- J Thomas VaughanJVJ Thomas Vaughan
- 15 August 2012
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (17) , 5651-5665
Abstract
Heating induced near deep brain stimulation (DBS) lead electrodes during magnetic resonance imaging with a 3 T transceive head coil was measured, modeled, and imaged in three cadaveric porcine heads (mean body weight = 85.47 ± 3.19 kg, mean head weight = 5.78 ± 0.32 kg). The effect of the placement of the extra-cranial portion of the DBS lead on the heating was investigated by looping the extra-cranial lead on the top, side, and back of the head, and placing it parallel to the coil's longitudinal axial direction. The heating was induced using a 641 s long turbo spin echo sequence with the mean whole head average specific absorption rate of 3.16 W kg(-1). Temperatures were measured using fluoroptic probes at the scalp, first and second electrodes from the distal lead tip, and 6 mm distal from electrode 1 (T(6 mm)). The heating was modeled using the maximum T(6 mm) and imaged using a proton resonance frequency shift-based MR thermometry method. Results showed that the heating was significantly reduced when the extra-cranial lead was placed in the longitudinal direction compared to the other placements (peak temperature change = 1.5-3.2 °C versus 5.1-24.7 °C). Thermal modeling and MR thermometry may be used together to determine the heating and improve patient safety online.Keywords
This publication has 27 references indexed in Scilit:
- Radiofrequency heating in porcine models with a “large” 32 cm internal diameter, 7 T (296 MHz) head coilMagnetic Resonance in Medicine, 2011
- Effect of the extracranial deep brain stimulation lead on radiofrequency heating at 9.4 Tesla (400.2 MHz)Journal of Magnetic Resonance Imaging, 2010
- Absolute temperature MR imaging with thulium 1,4,7,10‐tetraazacyclododecane‐1,4,7,10‐tetramethyl‐1,4,7,10‐tetraacetic acid (TmDOTMA−)Magnetic Resonance in Medicine, 2009
- A Generic Bioheat Transfer Thermal Model for a Perfused TissueJournal of Biomechanical Engineering, 2009
- Real‐time monitoring of radiofrequency ablation of rabbit liver by respiratory‐gated quantitative temperature MRIJournal of Magnetic Resonance Imaging, 2006
- Non‐invasive temperature imaging with thulium 1,4,7,10‐tetraazacyclododecane‐1,4,7,10‐tetramethyl‐1,4,7,10‐tetraacetic acid (TmDOTMA−)NMR in Biomedicine, 2006
- Non-invasive magnetic resonance thermometry using thulium-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate (TmDOTA-)International Journal of Hyperthermia, 2002
- The dielectric properties of biological tissues: I. Literature surveyPhysics in Medicine & Biology, 1996
- Design-adaptive Nonparametric RegressionJournal of the American Statistical Association, 1992
- A comparative study of ordinary cross-validation, v-fold cross-validation and the repeated learning-testing methodsBiometrika, 1989