Sensitive Identification of Microcystin-LR via a Reagent-Free and Reusable Electrochemical Biosensor Using a Methylene Blue-Labeled Aptamer
Open Access
- 22 July 2022
- journal article
- research article
- Published by MDPI AG in Biosensors
- Vol. 12 (8) , 556
Abstract
We report a methylene blue (MB)-modified electrochemical aptamer (E-AB) sensor for determining microcystin-LR (MC-LR). The signal transduction of the sensor was based on changes in conformation and position of MB induced by the binding between MC-LR and the modified aptamer probe. In the absence of MC-LR, an aptamer probe was considered partially folded. After combining aptamer and MC-LR, the configuration of the aptamer probe changed and facilitated the electron transfer between MB and the electrode surface. As a result, an increased current response was observed. We optimized the parameters and evaluated the electrochemical performance of the sensor using square wave voltammetry (SWV). MC-LR was measured from 1.0 to 750.0 ng/L with a detection limit of 0.53 ng/L. The reliability of the method was verified by the determination of MC-LR in environmental real samples, such as pond water and tap water. Moreover, we demonstrated that this reagent-less biosensor could be regenerated and reused after rinsing with deionized water with good accuracy and reproducibility. As a reusable and regenerable E-AB sensor, this rapid, reagent-free, and sensitive sensing platform will facilitate routine monitoring of MC-LR in actual samples.Keywords
Funding Information
- The National Natural Science Foundation of China (82073607, kq2001035, 202045008, 2022ZZTS0893)
- the Novel Coronavirus Pneumonia Emergency Special Science and Technology Plan of Changsha City (82073607, kq2001035, 202045008, 2022ZZTS0893)
- Central South University (82073607, kq2001035, 202045008, 2022ZZTS0893)
- the Central Universities of Central South University (82073607, kq2001035, 202045008, 2022ZZTS0893)
This publication has 34 references indexed in Scilit:
- Monitoring Approaches for a Toxic Cyanobacterial BloomEnvironmental Science & Technology, 2013
- A graphene and multienzyme functionalized carbon nanosphere-based electrochemical immunosensor for microcystin-LR detectionColloids and Surfaces B: Biointerfaces, 2013
- Determination of microcystin-LR in water by a label-free aptamer based electrochemical impedance biosensorTalanta, 2013
- Label-free immunosensing of microcystin-LR using a gold electrode modified with gold nanoparticlesMicrochimica Acta, 2011
- In situassembly of gold nanoparticles on nitrogen-doped carbon nanotubes for sensitive immunosensing of microcystin-LRChemical Communications, 2010
- A Mechanistic Study of Electron Transfer from the Distal Termini of Electrode-Bound, Single-Stranded DNAsJournal of the American Chemical Society, 2010
- Simple, Rapid, Sensitive, and Versatile SWNT−Paper Sensor for Environmental Toxin Detection Competitive with ELISANano Letters, 2009
- Comparing the Properties of Electrochemical-Based DNA Sensors Employing Different Redox TagsAnalytical Chemistry, 2009
- Portable optical immunosensor for highly sensitive detection of microcystin-LR in water samplesBiosensors and Bioelectronics, 2009
- Effects of Probe Length, Probe Geometry, and Redox-Tag Placement on the Performance of the Electrochemical E-DNA SensorAnalytical Chemistry, 2009