Upper extremity deep venous thrombosis and stenosis after implantation of pacemakers and defibrillators; A prospective study
Open Access
- 19 August 2017
- journal article
- research article
- Published by Walter de Gruyter GmbH in Romanian Journal of Internal Medicine
- Vol. 55 (3) , 139-144
Abstract
Background. Obstruction of the access vein following cardiac pacemaker and defibrillator implantation is a common complication. However, the exact incidence and contributing risk factors are unknown. The aim of this study is to determine the incidence and analyze the contribution of each risk factor. Methods. 57 consecutive patients candidate for their first transvenous pacemaker, implantable cardioverter-defibrillator (ICD), or cardiac resynchronization therapy device implantation were enrolled. After implantation, venography of the ipsilateral peripheral arm was performed. Patients underwent their second venography after the follow-up period of 3 to 6 months. Results. 42 patients (13 females, mean age 59.71 ± 12.33) completed the study. The followup venography showed significant venous obstruction (more than 50%) in 9 (21%) patients, but in none of the individuals, venography revealed total occlusion of the veins. Patients with obstruction had more leads in their veins (2.56 ± 0.53 vs 1.58 ± 0.71, P = 0.001). Venous obstruction was significantly more prevalent in patients with implanted cardiac resynchronization therapy device compared with an ICD or pacemaker (p = 0. 01). Age, gender, diabetes mellitus, hypertension, ischemic heart disease and antiplatelet consumption did not reveal any other contribution to the risk of thrombosis. In multivariate analysis, total lead number was a positive predictor for venous occlusion (P = 0.015, OR:19.2, and CI: 1.7-207.1). Conclusion. Venous obstruction is relatively frequent after pacemaker or ICD implantation. This study also shows that pacemaker and ICD leads have a similar risk for lead-related venous obstruction. However, patients with multiple leads are associated with an increased risk.Keywords
This publication has 21 references indexed in Scilit:
- Venous Stenosis and Occlusion in the Presence of Endocardial LeadsAdvances in Clinical and Experimental Medicine, 2015
- Prevalence of venous occlusion in patients referred for lead extraction: implications for tool selectionEP Europace, 2014
- 2012 ACCF/AHA/HRS Focused Update of the 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm AbnormalitiesJACC, 2012
- Incidence and predictors of subclavian vein obstruction following biventricular device implantationJournal of Interventional Cardiac Electrophysiology, 2010
- Predictors of venous obstruction following pacemaker or implantable cardioverter-defibrillator implantation: a contrast venographic study on 100 patients admitted for generator change, lead revision, or device upgradeEP Europace, 2007
- Age, Size, and Lead Factors Alone Do Not Predict Venous Obstruction in Children and Young Adults with Transvenous Lead SystemsJournal of Cardiovascular Electrophysiology, 2006
- Venous Thrombosis and Stenosis After Implantation of Pacemakers and DefibrillatorsJournal of Interventional Cardiac Electrophysiology, 2005
- Incidence and Risk Factors of Early Venous Thrombosis Associated with Permanent Pacemaker LeadsJournal of Cardiovascular Electrophysiology, 2004
- Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacementEP Europace, 2004