Comparison of PR and PI Controllers for Inverter Control in an Unbalanced Microgrid
Authors:
- 11 April 2021
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Abstract
High penetration of renewable-fed Inverter Based Resources(IBRs) will most likely be an integral part of microgrids in the near future. Since such microgrids will, in most cases, evolve from existing distribution feeders, it will be unbalanced in terms of loads, phases, and feeder impedances. Typical control strategy of a conventional inverter that follows the grid voltage and frequency, while injecting positive-sequence current can lead to undesirable performance, especially in the islanded mode of operation. So, for the proper functioning of these microgrids, there is a need for grid-forming inverters that can enable acceptable performance and coexist with conventional grid-following inverters that supply only positive-sequence currents. In addition to the control objectives, limiting of inverter output during faulted or overload conditions with a current limiter is essential. These control objectives can be implemented in both the synchronous reference frame (dq coordinates) and the natural reference frame (abc coordinates). However, a comparison of inverter response, dynamics, and implementation are needed to understand each controller's merit as relates to this specific topology. This paper compares the control performance of the two approaches for a highly unbalanced microgrid in grid-connected and islanded modes. Acceptable operating conditions with stability against disturbances and faults are the primary focus of this study.Keywords
Funding Information
- U.S.Department of Energy's Office of Energy Efficiency and Renewable Energy(EERE) (DE-EE0008774)
- Solar Energy Technologies Office (DE-EE0008774,20190382-01-CLE)
This publication has 17 references indexed in Scilit:
- Universal Droop Control of Inverters With Different Types of Output ImpedanceIEEE Access, 2016
- Control strategy for microgrid under three-phase unbalance conditionJournal of Modern Power Systems and Clean Energy, 2016
- Performance analysis of PR current controller for single-phase inverters2016
- A droop controller is intrinsically a phase-locked loop2013
- A comparative overview of large-scale battery systems for electricity storageRenewable and Sustainable Energy Reviews, 2013
- Control of Power Converters in AC MicrogridsIEEE Transactions on Power Electronics, 2012
- MicrogridsIEEE Power and Energy Magazine, 2007
- Practical Implementation of Delayed Signal Cancellation Method for Phase-Sequence SeparationIEEE Transactions on Power Delivery, 2006
- Proportional-resonant controllers and filters for grid-connected voltage-source convertersIEE Proceedings - Electric Power Applications, 2006
- A stable three-phase LCL-filter based active rectifier without damping2004