Pico-molar determination of lurasidone hydrochloride in pharmaceutical formulations using PVC-membrane bulk Miptode
Open Access
- 7 April 2026
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (20) , 17959-17971
Abstract
Lurasidone hydrochloride (LRH) is an important medication used for schizophrenia treatment, with minimal side effects of body weight loss, limited sedative capacity and minimal metabolic change; accordingly, its determination is vital, as it is recommended for psychological and memory problems. Molecularly imprinted (MIP) and non-imprinted polymers (NIP) were prepared, and their structures were confirmed by FTIR. MIP and NIP were used as ionophores in bulk membrane optodes (Miptode and Niptode) for LRH determination. Miptode incorporated MIP as an ionophore, tetraphenyl borate as an ion-exchanger, nitrophenyl octyl ether as a plasticizer, and ETH 2439 as a chromoionophore; the response mechanism involved host–guest MIP-LRH complexation via hydrogen bonding, as confirmed by FTIR, followed by deprotonation of the chromoionophore, which caused an absorbance decrease at 675 nm. Compared with Niptode and ion-exchanger-based optodes, Miptode exhibited a very wide concentration range of 10−11 to 10−4 M and a very low detection limit of 10 pM. The superior Miptode selectivity was confirmed by the separate solution and mixed solution methods; the mixed solution method exhibited changes in absorbance (% relative error) of 8, 33, and 29% for Miptode, Niptode, and the ion-exchanger-based optode, respectively. The wide linear concentration range, low detection limit, and high selectivity of Miptode were confirmed by the uniform particle size of the MIP at 47 nm and its homogeneous distribution, as observed by SEM and elemental mapping. Miptode was successfully applied to determine LRH in pure solutions, the pharmaceutical formulation Serodopamoun® tablets, and spiked urine samples, with reasonable accuracy (recovery: 98.5–102.3%) and high precision (relative standard deviation <0.81%). MIP is a suitable alternative for enhancing the ionophore library to prepare sensors for any analyte.Keywords
Funding Information
- Imam Mohammed Ibn Saud Islamic University (IMSIU-DDRSP2603)
This publication has 45 references indexed in Scilit:
- Fabrication of PF-127 Based Niosomal In Situ Gel for Intranasal Delivery of Lurasidone Hydrochloride and Optimization by Using 32 Factorial DesignBioNanoScience, 2024
- Molecularly Imprinted Potentiometric Sensor for Nanomolar Determination of Pioglitazone Hydrochloride in Pharmaceutical FormulationsElectroanalysis, 2021
- Progress on nanostructured electrochemical sensors and their recognition elements for detection of mycotoxins: A reviewBiosensors and Bioelectronics, 2018
- Molecularly imprinted polymer-based bulk optode for the determination of itopride hydrochloride in physiological fluidsBiosensors and Bioelectronics, 2016
- Computational Design, Synthesis and Application of a New Selective Molecularly Imprinted Polymer for Electrochemical DetectionElectroanalysis, 2016
- LC‐MS/MS assay for the determination of lurasidone and its active metabolite, ID‐14283 in human plasma and its application to a clinical pharmacokinetic studyBiomedical Chromatography, 2015
- Synthesis and application of a molecularly imprinted polymer for the voltammetric determination of famciclovirBiosensors and Bioelectronics, 2015
- Ion selective optodes: from the bulk to the nanoscaleAnalytical and Bioanalytical Chemistry, 2015
- Anion selective optical sensing with metalloporphyrin-doped polymeric filmsAnalytica Chimica Acta, 1993
- Synthesis and characterization of neutral hydrogen ion-selective chromoionophores for use in bulk optodesAnalytica Chimica Acta, 1993