Activation of QA devices and phantom materials under clinical scanning proton beams—a gamma spectrometry study
- 1 June 2018
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (11) , 115014
Abstract
Activation of detectors and phantoms used for commissioning and quality assurance of clinical proton beams may lead to radiation protection issues. Good understanding of the activation nuclide vectors involved is necessary to assess radiation risk for the personnel working with these devices on a daily basis or to fulfill legal requirements regarding transport of radioactive material and its release to the public. 11 devices and material samples were irradiated with a 220 MeV proton pencil beam (PBS, Proton Therapy Center, Prague). This study focuses on devices manufactured by IBA Dosimetry GmbH: MatriXX PT, PPC05, Stingray, Zebra, Lynx, a Blue Phantom rail and samples of RW3, PMMA, titanium, copper and carbon fibre plastic. Monitor units (MU) were monitored during delivery. Gamma spectrometry was then performed for each item using a HPGe detector, with a focus on longer lived gamma emitting radionuclides. Activities were quantified for all found isotopes and compared to relevant legal limits for exemption and clearance of radioactive objects. Activation was found to be significant after long irradiation sessions, as done during commissioning of a proton therapy room. Some of the investigated devices may also cumulate activity in time, depending on the scenario of periodic irradiation in routine clinical practice. However, the levels of activity and resulting beta/gamma doses are more comparable to internationally recommended concentration limits for exemption than to dose limits for radiation workers. Results of this study will help to determine nuclide inventories required by some legal authorities for radiation protection purposes.Keywords
Funding Information
- IBA Dosimetry GmbH
This publication has 17 references indexed in Scilit:
- Measured Neutron Spectra and Dose Equivalents From a Mevion Single-Room, Passively Scattered Proton System Used for Craniospinal IrradiationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2016
- Accurate Monte Carlo modeling of cyclotrons for optimization of shielding and activation calculations in the biomedical fieldRadiation Physics and Chemistry, 2015
- Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systemsMedical Physics, 2015
- Activation cross sections for production of 7Be by proton and deuteron induced reactions on 9Be: Protons up to 65MeV and deuterons up to 50MeVApplied Radiation and Isotopes, 2014
- Quality assurance of proton beams using a multilayer ionization chamber systemMedical Physics, 2013
- Shielding calculation for the Proton-Therapy-Center in Prague, Czech RepublicRadioprotection, 2012
- Induced radioactivity in a patient-specific collimator used in proton therapyNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2010
- Secondary neutrons in clinical proton radiotherapy: A charged issueRadiotherapy and Oncology, 2008
- Simulation of organ-specific patient effective dose due to secondary neutrons in proton radiation treatmentPhysics in Medicine & Biology, 2005
- Limits for qualitative detection and quantitative determination. Application to radiochemistryAnalytical Chemistry, 1968