Real world validation of the nonhyperemic index of coronary artery stenosis severity—Resting full‐cycle ratio—RE‐VALIDATE
- 21 October 2019
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 96 (1) , E53-E58
Abstract
Objective: The primary objective was to demonstrate diagnostic equivalence between RFR and iFR in clinical practice.Background: The instantaneous wave‐free ratio (iFR), a nonhyperemic pressure ratio (NHPR), has been shown to be noninferior to fractional flow reserve (FFR) in determining coronary artery stenosis severity in intermediate lesions. However, iFR has a number of inherent limitations, including sensitive landmarking of the pressure waveform and the assumption that maximal flow and minimal microcirculatory resistance occur during a fixed period within diastole. The resting full‐cycle ratio (RFR) is a novel NHPR which evaluates the entire cardiac cycle independent of the ECG, landmark identification, and timing within the cardiac cycle.Methods: RE‐VALIDATE RFR was designed to determine the diagnostic utility of RFR for the physiological assessment of coronary artery disease in clinical practice compared to iFR. RFR was also tested for equivalence (1% margin), diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), areas under the receiver operated characteristic curve (AUC), and correlations compared to calculated iFR (iFRcalc).Results: From two centers, 501 blinded rest‐ and hyperemic pressure recordings from 431 patients were suitable for analysis according to a core laboratory. The mean FFR, RFR, and iFRcalc were 0.80 ± 0.09, 0.90 ± 0.08, and 0.90 ± 0.08, respectively. Based on a binary cut‐off approach (RFR/iFR ≤0.89), RFR demonstrated equivalence with iFRcalc (95% confidence interval: 0.025–0.019) with overall diagnostic accuracy 97.8%, sensitivity 97.8%, specificity 97.8%, PPV 96.2%, NPV 98.7%, and AUC 0.96 (0.94–0.97, p < .001). RFR had a mean bias 0.003 (95% limits of agreement: 0.019, −0.025).Conclusions: RFR was equivalent to iFR in clinical practice. RFR is an alternative NHPR, avoiding the need for hyperemic agents, thus potentially reducing side effects, procedural time and cost compared to FFR.Keywords
This publication has 16 references indexed in Scilit:
- Accuracy of Fractional Flow Reserve Measurements in Clinical PracticeJACC: Cardiovascular Interventions, 2017
- Use of the Instantaneous Wave-free Ratio or Fractional Flow Reserve in PCIThe New England journal of medicine, 2017
- Instantaneous Wave-free Ratio versus Fractional Flow Reserve to Guide PCINew England Journal of Medicine, 2017
- Diagnostic Performance of Resting and Hyperemic Invasive Physiological Indices to Define Myocardial IschemiaJACC: Cardiovascular Interventions, 2017
- Prospective Assessment of the Diagnostic Accuracy of Instantaneous Wave-Free Ratio to Assess Coronary Stenosis RelevanceJACC: Cardiovascular Interventions, 2015
- The Instantaneous wave-Free Ratio (iFR) pullback: a novel innovation using baseline physiology to optimise coronary angioplasty in tandem lesionsCardiovascular Revascularization Medicine, 2015
- Multicenter Core Laboratory Comparison of the Instantaneous Wave-Free Ratio and Resting P /P With Fractional Flow ReserveJACC, 2014
- Fractional Flow Reserve–Guided PCI versus Medical Therapy in Stable Coronary DiseaseThe New England journal of medicine, 2012
- Development and Validation of a New Adenosine-Independent Index of Stenosis Severity From Coronary Wave–Intensity AnalysisJACC, 2012
- Fractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary InterventionThe New England journal of medicine, 2009