Backdraft in Descensionally Ventilated Mine Fire
Authors:
- 1 May 2005
- journal article
- research article
- Published by SAGE Publications in Journal of Fire Sciences
- Vol. 23 (3) , 261-271
Abstract
The backdraft in an underground mine tunnel fire is investigated by means of experimental simulation. According to the results, such a backdraft phenomenon is different from a general one in a compartment fire. A backdraft of tunnel fire takes place in an open system with flowing gases and no newly formed vents are needed to result in it under such an occasion. The backdraft occurs with the reversal of descensionally ventilated airflow. The results obtained extend the range where a backdraft can occur and promote a better understanding of the backdraft phenomenon.Keywords
This publication has 7 references indexed in Scilit:
- Mitigation of backdraft with water mist: A reduced‐scale experimental studyProcess Safety Progress, 2003
- Experimental study of back-draft in a compartment with openings of different geometriesCombustion and Flame, 2003
- Critical condition of backdraft in compartment fires: a reduced-scale experimental studyJournal of Loss Prevention in the Process Industries, 2003
- Study on salt water modeling of gravity currents prior to backdrafts using flow visualization and digital particle image velocimetryExperiments in Fluids, 2002
- Experimental Study on the Mitigation of Backdraft in Compartment Fires with Water MistJournal of Fire Sciences, 2002
- The development and mitigation of backdraft: a real-scale shipboard studyFire Safety Journal, 1999
- Exploratory backdraft experimentsFire Technology, 1993