Linearity of the instrumental intensity scale in TOF‐SIMS—a VAMAS interlaboratory study
- 25 March 2011
- journal article
- research article
- Published by Wiley in Surface and Interface Analysis
- Vol. 44 (1) , 1-14
Abstract
A VAMAS interlaboratory study involving 21 time‐of‐flight SIMS instruments from nine countries has been conducted to evaluate the linearity of the instrumental intensity scale and procedures for intensity correction. Analysts were supplied, by National Physical Laboratory (NPL), with a protocol for analysis (closely aligned with ISO 23830) together with a reference material of polytetrafluoroethylene (PTFE) tape. The primary ion beam current is varied to provide secondary ion intensities that span the linear to nonlinear regime. The natural carbon isotope ratios 12 C x F y + / 13 C 12 C x −1 F y + for five peaks are used to evaluate the linearity, without a need to measure the ion beam current. A method is given for determining the linearity as a function of secondary ion intensity, with and without dead time correction. It is found that single ion counting statistics is closely obeyed, and the linearity achievable is generally excellent with careful application of dead time correction. Three quarters of instruments in the study achieved better than 95% linearity at a count rate of 0.8 measured counts per pulse, equivalent to 1.6 secondary ions impinging the detector per primary ion pulse. We discuss factors affecting linearity and the precise application of dead time correction and give guidance for practical analysis. This includes suboptimal detector efficiency, inhomogeneous intensities across the rastered area, inadequate charge compensation, and the choice of peak integration limits. The interlaboratory study shows that the method to determine linearity is generally applicable, robust and provides an excellent basis for the development of an ISO standard. © Crown copyright 2011. Reproduced with the permission of Her Majesty's Stationery Office. Published by John Wiley & Sons, Ltd.Keywords
This publication has 18 references indexed in Scilit:
- VAMAS interlaboratory study on organic depth profiling. Part I: Preliminary reportSurface and Interface Analysis, 2011
- Static SIMS–VAMAS interlaboratory study for intensity repeatability, mass scale accuracy and relative quantificationSurface and Interface Analysis, 2010
- Sample Cooling or Rotation Improves C60 Organic Depth Profiles of Multilayered Reference Samples: Results from a VAMAS Interlaboratory StudyThe Journal of Physical Chemistry B, 2009
- Static TOF‐SIMS. A VAMAS interlaboratory study. Part II — accuracy of the mass scale and G‐SIMS compatibilitySurface and Interface Analysis, 2007
- TOF-SIMS: Accurate mass scale calibrationJournal of the American Society for Mass Spectrometry, 2006
- Static TOF‐SIMS — a VAMAS interlaboratory study. Part I. Repeatability and reproducibility of spectraSurface and Interface Analysis, 2005
- Influence of primary ion bombardment conditions on the emission of molecular secondary ionsApplied Surface Science, 2004
- Isotopic ratio measurements by time-of-flight secondary ion mass spectrometryInternational Journal of Mass Spectrometry, 2001
- Static SIMS inter-laboratory studySurface and Interface Analysis, 2000
- Measurements of dead time and characterization of ion counting systems for mass spectrometryReview of Scientific Instruments, 1998