Objective: To evaluate the outcome of TEVAR for TBAD and revascularization of LSA with Castor single-branched stent-graft. Summary background data: One-stage thoracic endovascular aortic repair (TEVAR) and revascularization of left subclavian artery (LSA) of type B aortic dissection (TBAD) with off-the-shelf stent-graft is limited. Methods: A multicenter study consisting of consecutive patients from four different centers in China treated with Castor single-branched stent-graft for TBAD was conducted. Rate of technical success, mortality, complications, and reinterventions were evaluated. Results: Between September 2018 and April 2022, 180 consecutive patients with TBAD received TEVAR with Castor single-branched stent-graft. Technical success was achieved in all patients. The mean oversize ratio at the proximal landing zone was 4.9±3.8% (median, 3.7; IQR, 2.0–6.9%). Five patients died within the first 30 days after the operation or during hospitalization. Early reintervention was performed in one case. The median follow-up was 18.0 months (IQR, 13–24 months). Five patients died during follow-up, including three cases of respiratory failure, one case of immune thrombocytopenia purpura, and one case of a cerebral hemorrhage. Three patients had reintervention. In total, three cases of stroke were recorded, which were all within 30 days after the operation. Image data at 1 year presented complete thrombosis in 97.1% cases for the false lumen covered by the stent-graft. Conclusions: TEVAR with Castor device for treatment of TBAD and revascularization of LSA is a feasible and safe technique. The deployment procedure is safe, easy, and accurate. Castor devices meets the hemodynamical and biomechanical requirement of elastic aorta and could restore the physiological blood flow pattern of LSA.Keywords
This publication has 34 references indexed in Scilit:
- Society for Vascular Surgery (SVS) and Society of Thoracic Surgeons (STS) reporting standards for type B aortic dissectionsJournal of Vascular Surgery, 2020
- Editor's Choice – Endovascular vs. Open Repair for Abdominal Aortic Aneurysm: Systematic Review and Meta-analysis of Updated Peri-operative and Long Term Data of Randomised Controlled TrialsEuropean Journal of Vascular and Endovascular Surgery, 2020
- Meta-analysis of the outcomes of revascularization after intentional coverage of the left subclavian artery for thoracic endovascular aortic repairJournal of Vascular Surgery, 2019
- Editor's Choice – Current Options and Recommendations for the Treatment of Thoracic Aortic Pathologies Involving the Aortic Arch: An Expert Consensus Document of the European Association for Cardio-Thoracic Surgery (EACTS) & the European Society for Vascular Surgery (ESVS)European Journal of Vascular and Endovascular Surgery, 2019
- Low Peak dP/dt in the Descending Aorta in Patients After Successful Aortic Arch RepairPediatric Cardiology, 2017
- Thoracic endovascular aortic repair with branched Inoue Stent Graft for arch aortic aneurysmsJournal of Vascular Surgery, 2017
- Mid-term Results of Chimney and Periscope Grafts in Supra-aortic Branches in High Risk PatientsEuropean Journal of Vascular and Endovascular Surgery, 2017
- Results of the Valiant Mona LSA early feasibility study for descending thoracic aneurysmsJournal of Vascular Surgery, 2015
- Analysis of Stroke after TEVAR Involving the Aortic ArchEuropean Journal of Vascular and Endovascular Surgery, 2012