Mammal, reptile, amphibian and invertebrate electrocutions on electric power networks in Iran
Open Access
- 23 March 2026
- journal article
- research article
- Published by Cambridge University Press (CUP) in Oryx
- Vol. 60 (1) , 1-8
Abstract
Electrical power systems are a ubiquitous part of the Anthropocene. Wildlife interactions with these systems can be positive, for example when natural nesting substrates are limited, but are frequently negative, for example when nests catch fire or nesting individuals are electrocuted. Electrocution research focuses primarily on birds because they, especially large species, are particularly prone to electrocution. However, many other animals are also electrocuted. To explore non-avian electrocutions, we used crowdsourced data from Iran, where electric utility personnel frequently describe unusual incidents on electric industry-focused social media channels. In posts from January 2014 to December 2023, we identified 120 reports of non-avian electrocutions involving mammals (74%), reptiles (24%), amphibians (1%) and invertebrates (< 1%). Most (91%) incidents involved correctly operating electrical systems, indicating that the design of these electrical systems did not account for potential animal contacts. A few (9%) involved malfunctioning electrical components (overturned or energized power poles) that would also have been hazardous to humans. The greatest number of electrocutions occurred as a result of contact with low-voltage and ground-mounted equipment. For example, 220–600 V freestanding switchboards accounted for about one-third of electrocutions. Many of the documented incidents involved outages (n = 71), or outages together with fire ignitions (n = 8), indicating cascading effects on human populations and the environment. Mitigation measures to prevent these incidents are widely available, and should be used throughout the electrical system. Future research should document and quantify non-avian incidents beyond Iran, to better understand the impact of electrical systems on non-avian wildlife.Keywords
This publication has 20 references indexed in Scilit:
- Development of a National Guideline: An Authorized Step Toward Coexistence Between Avian Populations and Power Companies in IranJournal of International Wildlife Law & Policy, 2022
- Crowd‐sourced reporting of birds nesting on power lines in IranWildlife Society Bulletin, 2022
- Wildland fires ignited by avian electrocutionsWildlife Society Bulletin, 2022
- Electrocutions in free-living black-tufted marmosets (Callithrix penicillata) in anthropogenic environments in the Federal District and surrounding areas, BrazilPrimates, 2019
- Rare cases of carnivore mortality due to electric power distribution lines in IranZoology and Ecology, 2018
- Spatial Patterns of Primate Electrocutions in Diani, KenyaInternational Journal of Primatology, 2018
- Wildfires as collateral effects of wildlife electrocution: An economic approach to the situation in Spain in recent yearsScience of The Total Environment, 2018
- Drivers of power line use by white storks: A case study of birds nesting on anthropogenic structuresJournal of Applied Ecology, 2018
- Economic costs of electrical system instability and power outages caused by snakes on the Island of GuamInternational Biodeterioration & Biodegradation, 2002
- Bird interactions with utility structures: collision and electrocution, causes and mitigating measuresIbis, 1994