Self-Calibration of an Industrial Robot Using a Novel Affordable 3D Measuring Device
Open Access
Abstract
This work shows the feasibility of calibrating an industrial robot arm through an automated procedure using a new, low-cost, wireless measuring device mounted on the robot’s flange. The device consists of three digital indicators that are fixed orthogonally to each other on an aluminum support. Each indicator has a measuring accuracy of 3 µm. The measuring instrument uses a kinematic coupling platform which allows for the definition of an accurate and repeatable tool center point (TCP). The idea behind the calibration method is for the robot to bring automatically this TCP to three precisely-known positions (the centers of three precision balls fixed with respect to the robot’s base) and with different orientations of the robot’s end-effector. The self-calibration method was tested on a small six-axis industrial robot, the ABB IRB 120 (Vasteras, Sweden). The robot was modeled by including all its geometrical parameters and the compliance of its joints. The parameters of the model were identified using linear regression with the least-square method. Finally, the performance of the calibration was validated with a laser tracker. This validation showed that the mean and the maximum absolute position errors were reduced from 2.628 mm and 6.282 mm to 0.208 mm and 0.482 mm, respectively.Keywords
This publication has 24 references indexed in Scilit:
- A flexible calibration method connecting the joint space and the working space of industrial robotsIndustrial Robot: the international journal of robotics research and application, 2018
- Robot calibration using a portable photogrammetry systemRobotics and Computer-Integrated Manufacturing, 2018
- A Rapid Coordinate Transformation Method Applied in Industrial Robot Calibration Based on Characteristic Line CoincidenceSensors, 2016
- Review on kinematics calibration technology of serial robotsInternational Journal of Precision Engineering and Manufacturing, 2014
- Absolute robot calibration with a single telescoping ballbarPrecision Engineering, 2014
- Comparison of two calibration methods for a small industrial robot based on an optical CMM and a laser trackerRobotica, 2013
- A New Full Pose Measurement Method for Robot CalibrationSensors, 2013
- Absolute calibration of an ABB IRB 1600 robot using a laser trackerRobotics and Computer-Integrated Manufacturing, 2013
- Vision-based automatic theodolite for robot calibrationIEEE Transactions on Robotics and Automation, 1991
- Autonomous calibration of single-loop closed kinematic chains formed by manipulators with passive endpoint constraintsIEEE Transactions on Robotics and Automation, 1991