Abstract
We report here for the first time on the use of functional microemulsions in potentiometric assays to remove dilute interferences from solution when measuring high concentrations of analyte. The microemulsions are similarly formulated to the ion‐selective membrane used in the measurement and act as sacrificial material. They are here stabilized by the triblock copolymer pluronic F‐127 and contain the chloride salt of the tridodecylmethylammonium cation, which also serves as anion‐exchanger in the membrane electrode. Both membrane and microemulsion are preconditioned with chloride. If an anionic interference is present at moderate concentration, the rapid equilibration with the functionalized microemulsion results in a quantitative removal. The principle is explored with salicylate as common interference in the detection of chloride in physiological samples. The data agree well to an equilibrium ion‐exchange model for the microemulsion. Salicylate levels up to millimolar can be effectively removed. Unfortunately, quaternary ammonium salt from the microemulsion is found to contaminate the ion‐selective membrane phase. Indeed, a cation‐exchanging valinomycin membrane in contact with concentrated anion‐exchanging microemulsions shows a large potential increase. This indicates that the membrane changes from cation to anion permselectivity. This contamination of the membrane by the microemulsion phase must be overcome for a practical application of the approach.Keywords
This publication has 33 references indexed in Scilit:
- Anion selectivity at the aqueous/polymeric membrane interface: A streaming current study of potentiometric Hofmeister effectElectrochimica Acta, 2012
- Chloride selective potentiometric sensor based on a newly synthesized hydrogen bonding anion receptorElectrochimica Acta, 2009
- Selectivity enhancement of anion-responsive electrodes by pulsed chronopotentiometryAnalytica Chimica Acta, 2007
- Investigation of chloride sensitive ISFETs with different membrane compositions suitable for medical applicationsAnalytica Chimica Acta, 2004
- Improving the Detection Limit of Anion-Selective Electrodes: An Iodide-Selective Membrane with a Nanomolar Detection LimitAnalytical Chemistry, 2003
- A Chloride Ion-Selective Solvent Polymeric Membrane Electrode Based on a Hydrogen Bond Forming IonophoreAnalytical Chemistry, 1997
- Asymmetric membrane-based potentiometric solid-state ion sensorsSensors and Actuators B: Chemical, 1996
- Asymmetric cellulose acetate membrane-based carbonate- and chloride-selective electrodesAnalytica Chimica Acta, 1995
- Asymmetric carbonate ion-selective cellulose acetate membrane electrodes with reduced salicylate interferenceAnalytical Chemistry, 1993
- Determination of true selectivity coefficients of neutral carrier calcium selective electrodeMicrochimica Acta, 1991