Computational fluid dynamic analysis of flow velocity waveform notching in umbilical arteries
Open Access
- 1 January 2011
- journal article
- Published by American Physiological Society in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Vol. 300 (1) , R76-R84
Abstract
Umbilical artery Doppler velocimetry waveform notching has long been associated with umbilical cord abnormalities, such as distortion, torsion, and/or compression (i.e., constriction). The physical mechanism by which the notching occurs has not been elucidated. Flow velocity waveforms (FVWs) from two-dimensional pulsatile flows in a constricted channel approximating a compressed umbilical cord are analyzed, leading to a clear relationship between the notching and the constriction. Two flows with an asymmetric, semi-elliptical constriction are computed using a stabilized finite-element method. In one case, the constriction blocks 75% of the flow passage, and in the other the constriction blocks 85%. Channel width and prescribed flow rates at the channel inflow are consistent with typical cord diameters and flow rates reported in the literature. Computational results indicate that waveform notching is caused by flow separation induced by the constriction, giving rise to a vortex (core) wave and associated eddies. Notching in FVWs based on centerline velocity (centerline FVW) is directly related to the passage of an eddy over the point of measurement on the centerline. Notching in FVWs based on maximum cross-sectional velocity (envelope FVW) is directly related to acceleration and deceleration of the fluid along the vortex wave. Results show that notching in envelope FVW is not present in flows with less than a 75% constriction. Furthermore, notching disappears as the vortex wave is attenuated at distances downstream of the constriction. In the flows with 75 and 85% constriction, notching of the envelope FVW disappears at ∼3.8 and ∼4.3 cm (respectively) downstream of the constriction. These results are of significant medical importance, given that envelope FVW is typically measured by commercial Doppler systems.Keywords
This publication has 12 references indexed in Scilit:
- Abnormal arterial flows by a distributed model of the fetal circulationAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2006
- A coupled momentum method for modeling blood flow in three-dimensional deformable arteriesComputer Methods in Applied Mechanics and Engineering, 2006
- Reference ranges for serial measurements of blood velocity and pulsatility index at the intra‐abdominal portion, and fetal and placental ends of the umbilical arteryUltrasound in Obstetrics & Gynecology, 2005
- Waveform Dependence of Pulsatile Flow in a Stenosed ChannelJournal of Biomechanical Engineering, 2000
- Flows in Stenotic VesselsAnnual Review of Fluid Mechanics, 2000
- Hemodynamic model for analysis of Doppler ultrasound indexes of umbilical blood flowAmerican Journal of Physiology-Heart and Circulatory Physiology, 1999
- A Truly Knotted CordAustralian and New Zealand Journal of Obstetrics and Gynaecology, 1998
- The Effect of Constriction Size on the Pulsatile Flow in a ChannelJournal of Fluids Engineering, 1995
- Pulsatile Flow in a Constricted ChannelJournal of Biomechanical Engineering, 1992
- Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is knownThe Journal of Physiology, 1955