Biomechanical properties of plate constructs for feline ilial fracture gap stabilization
- 13 November 2018
- journal article
- research article
- Published by Wiley in Veterinary Surgery
- Vol. 48 (1) , 88-95
Abstract
Objective To determine the biomechanical properties of plating techniques for comminuted feline ilial fractures. Study design Ex vivo study on 40 paired feline hemipelves. Sample population Forty paired fresh-frozen hemipelves that had been collected from 20 cats aged 2-6 years and weighing 4.0-5.5 kg. Methods A transverse 3-mm gap was created in each ilium. Hemipelves were fixed with one of the following methods (n = 10 per group): (1) a dorsal plate and nonlocking screws, (2) a lateral plate and nonlocking screws, (3) a lateral plate and locking screws, or (4) a lateral and dorsal locking compression plate using nonlocking screws. Each specimen was subjected to incremental, sinusoidal cyclic loading until failure, defined as 10-mm displacement. The initial stiffness and number of cycles required to reach 1-, 2-, 5-, and 10-mm axial displacement were statistically analyzed. Results The initial stiffness and number of cycles to failure were higher in specimens fixed with double nonlocking plates than in all other fixations (P < .05) except specimens fixed with lateral locking plate at 10-mm displacement (P = .44). Locking implants withstood more cycles to 5- (P < .05) and 10-mm (P < .05) displacement compared with other single-plate nonlocking groups. Screw loosening occurred only in the 3 nonlocking fixations. Conclusion Double plating improved stiffness and resistance to failure of comminuted feline ilial fracture constructs compared with all other fixations. Single locking plates produced superior constructs compared with single nonlocking constructs. Clinical significance Locking implants are recommended to repair comminuted feline ilial fractures for their extended fatigue life and resistance to screw loosening. Orthogonal plating offers a strong nonlocking alternative.Keywords
Funding Information
- AOVET ARI Collaborative Research
This publication has 22 references indexed in Scilit:
- Angular Stability Potentially Permits Fewer Locking Screws Compared With Conventional Locking in Intramedullary Nailed Distal Tibia Fractures: A Biomechanical StudyJournal of Orthopaedic Trauma, 2011
- Single cycle to failure in torsion of three standard and five locking plate constructsVeterinary and Comparative Orthopaedics and Traumatology, 2011
- Repair of a transverse ilial fracture in a cat using an intramedullary pinVeterinary and Comparative Orthopaedics and Traumatology, 2010
- Feline Ilial Fractures: A Prospective Study of Dorsal Plating and Comparison with Lateral PlatingVeterinary Surgery, 2009
- Feline Ilial Fractures: Assessment of Screw Loosening and Pelvic Canal Narrowing After Lateral PlatingVeterinary Surgery, 2009
- Appendicular fracture repair in dogs using the locking compression plate system: 47 casesVeterinary and Comparative Orthopaedics and Traumatology, 2009
- Repair of long-bone fractures in cats and small dogs with the Unilock mandible locking plate systemVeterinary and Comparative Orthopaedics and Traumatology, 2009
- Radiographic examination and outcome in consecutive feline trauma patientsVeterinary and Comparative Orthopaedics and Traumatology, 2008
- Use of T-plates for the stabilisation of supracotyloid ilial fractures in 18 cats and five dogsVeterinary and Comparative Orthopaedics and Traumatology, 2008
- Mechanical Evaluation of Three Methods of Plating Distal Radial OsteotomiesVeterinary Surgery, 1992