The bone diagnostic instrument II: Indentation distance increase
Authors:
- 1 June 2008
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 79 (6) , 064303
Abstract
The bone diagnostic instrument (BDI) is being developed with the long-term goal of providing a way for researchers and clinicians to measure bone material properties of human bone in vivo. Such measurements could contribute to the overall assessment of bone fragility in the future. Here, we describe an improved BDI, the Osteoprobe II™. In the Osteoprobe II™, the probe assembly, which is designed to penetrate soft tissue, consists of a reference probe (a 22 gauge hypodermic needle) and a test probe (a small diameter, sharpened rod) which slides through the inside of the reference probe. The probe assembly is inserted through the skin to rest on the bone. The distance that the test probe is indented into the bone can be measured relative to the position of the reference probe. At this stage of development, the indentation distance increase (IDI) with repeated cycling to a fixed force appears to best distinguish bone that is more easily fractured from bone that is less easily fractured. Specifically, in three model systems, in which previous mechanical testing and/or tests reported here found degraded mechanical properties such as toughness and postyield strain, the BDI found increased IDI. However, it must be emphasized that, at this time, neither the IDI nor any other mechanical measurement by any technique has been shown clinically to correlate with fracture risk. Further, we do not yet understand the mechanism responsible for determining IDI beyond noting that it is a measure of the continuing damage that results from repeated loading. As such, it is more a measure of plasticity than elasticity in the bone.Keywords
This publication has 36 references indexed in Scilit:
- Exercise-induced changes in the cortical bone of growing mice are bone- and gender-specificBone, 2007
- Cooperative deformation of mineral and collagen in bone at the nanoscaleProceedings of the National Academy of Sciences, 2006
- Evidence for an elementary process in bone plasticity with an activation enthalpy of 1 eVJournal of The Royal Society Interface, 2006
- Age-related change in the damage morphology of human cortical bone and its role in bone fragilityBone, 2006
- Effects of damage morphology on cortical bone fragilityBone, 2005
- Effect of aging on the toughness of human cortical bone: evaluation by R-curvesBone, 2004
- Influence of the degradation of the organic matrix on the microscopic fracture behavior of trabecular boneBone, 2004
- Measurement of hardness and elastic modulus by instrumented indentation: Advances in understanding and refinements to methodologyJournal of Materials Research, 2004
- Microdamage and mechanical behaviour: predicting failure and remodelling in compact boneJournal of Anatomy, 2003
- The role of collagen in the declining mechanical properties of aging human cortical boneJournal of Biomedical Materials Research, 1999