Purpose To assess the impact of using inner wall vs. outer wall measurements on stent-graft sizing for endovascular repair of abdominal aortic aneurysm (AAA). Methods Preoperative static and electrocardiographically-gated 64-slice computed tomographic angiography (CTA) datasets were acquired on 40 consecutive AAA patients (29 men; mean age 78.9±6 years, range 75–89). On static images, the aortic neck diameters were manually measured twice by 2 readers at 3 clinically relevant levels (supra-, juxta-, and infrarenal). The measurements were obtained from intima-to-intima (inner wall) and from adventitia-to-adventitia (outer wall). Dynamically reconstructed scans were also reviewed in each phase of the cardiac cycle to identify inner and outer minimum/maximum diameters. Using inner and outer wall measurements performed on static images, readers selected the size of a stent-graft that required inner neck diameter measurements and then one that required outer wall diameters. To calculate the relative oversizing, each selected stent-graft size was compared to that obtained using dynamic measurements. Oversizing 30% was considered inadequate. Results Mean variations for the inner and outer wall diameters of 9.75%±4.01% and 8.66%±3.71%, respectively, were recorded on static CTAs; the absolute changes in diameters were 1.82±0.63 mm and 1.91±0.64 mm, respectively. No statistically significant differences were found relative to aortic pulsatility at the 3 levels in the neck for the inner or outer wall diameters. Significant variability was seen between inner (mean 20.8±3.4 mm) vs. outer (mean 23.7±4.3 mm; pConclusions These data suggest that stent-graft sizing should follow the manufacturer's recommendations for using inner or outer diameter references based on dynamic patterns (mean value between diastolic and systolic diameters suggested).Keywords
This publication has 18 references indexed in Scilit:
- Aneurysm Rupture after EVAR: Can the Ultimate Failure be Predicted?European Journal of Vascular and Endovascular Surgery, 2009
- Secondary interventions following endovascular abdominal aortic aneurysm repair using current endografts. A EUROSTAR reportJournal of Vascular Surgery, 2006
- Proximal Type I Endoleak After Endovascular Abdominal Aortic Aneurysm Repair: Predictive FactorsAnnals of Vascular Surgery, 2004
- Stent graft migration after endovascular aneurysm repair: importance of proximal fixationJournal of Vascular Surgery, 2003
- Lessons learnt from the EUROSTAR registry on endovascular repair of abdominal aortic aneurysm repairEuropean Journal of Radiology, 2001
- Risk Factors for Endoleak and the Evidence for Stent-graft Oversizing in Patients Undergoing Endovascular Aneurysm RepairEuropean Journal of Vascular and Endovascular Surgery, 2001
- Mid-term results after endovascular repair of the abdominal aortic aneurysmJournal of Vascular Surgery, 2001
- Endoluminal Aortic Aneurysm Repair Using a Balloon-Expandable Stent-Graft Device: A Progress ReportAnnals of Vascular Surgery, 1994
- Preoperative assessment of abdominal aortic aneurysm: The value of helical and three-dimensional computed tomographyJournal of Vascular Surgery, 1994
- Transfemoral Intraluminal Graft Implantation for Abdominal Aortic AneurysmsAnnals of Vascular Surgery, 1991