Strategies for Using Postcolumn Infusion of Standards to Correct for Matrix Effect in LC-MS-Based Quantitative Metabolomics
Open Access
- 15 November 2024
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 35 (12) , 3286-3295
Abstract
The matrix effect limits the accuracy of quantitation of the otherwise popular metabolomics technique liquid chromatography coupled to mass spectrometry (LC-MS). The gold standard to correct for this phenomenon, whereby compounds coeluting with the analyte of interest cause ionization enhancement or suppression, is to quantify an analyte based on the peak area ratio with an isotopologue added to the sample as an internal standard. However, these stable isotopes are expensive and sometimes unavailable. Here, we describe an alternative approach: matrix effect correction and quantifying analytes using a signal ratio with a postcolumn infused standard (PCIS). Using an LC-MS/MS method for eight endocannabinoids and related metabolites in plasma, we provide strategies to select, optimize, and evaluate PCIS candidates. Based on seven characteristics, the structural endocannabinoid analogue arachidonoyl-2 '-fluoroethylamide was selected as a PCIS. Three methods to evaluate the PCIS correction vs no correction showed that PCIS correction improved values for the matrix effect, precision, and dilutional linearity of at least six of the analytes to within acceptable ranges. PCIS correction also resulted in parallelization of calibration curves in plasma and neat solution, for six of eight analytes even with higher accuracy than peak area ratio correction with their stable isotope labeled internal standard, i.e., the gold standard. This enables quantification based on neat solutions, which is a significant step toward absolute quantification. We conclude that PCIS has great, but so far underappreciated, potential in accurate LC-MS quantification.Keywords
All Related Versions
Funding Information
- Medical Delta
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (024.004.017, 175.2019.032)
This publication has 30 references indexed in Scilit:
- Signaling lipids as diagnostic biomarkers for ocular surface cicatrizing conjunctivitisJournal of Molecular Medicine, 2020
- Using post‐column infused internal standard assisted quantitative metabolomics for establishing prediction models for breast cancer detectionRapid Communications in Mass Spectrometry, 2019
- Development and application of a UHPLC–MS/MS metabolomics based comprehensive systemic and tissue-specific screening method for inflammatory, oxidative and nitrosative stressAnalytical and Bioanalytical Chemistry, 2018
- Post-column infusion of internal standard quantification for liquid chromatography-electrospray ionization-tandem mass spectrometry analysis – Pharmaceuticals in urine as example approachJournal of Chromatography A, 2018
- Using a postcolumn-infused internal standard for correcting the matrix effects of urine specimens in liquid chromatography–electrospray ionization mass spectrometryJournal of Chromatography A, 2014
- Quantitative profiling of oxylipins through comprehensive LC-MS/MS analysis: application in cardiac surgeryAnalytical and Bioanalytical Chemistry, 2012
- Quantitative Bioanalytical Methods Validation and Implementation: Best Practices for Chromatographic and Ligand Binding AssaysPharmaceutical Research, 2007
- Stable isotopically labeled internal standards in quantitative bioanalysis using liquid chromatography/mass spectrometry: necessity or not?Rapid Communications in Mass Spectrometry, 2005
- Adduct formation in quantitative bioanalysis: Effect of ionization conditions on paclitaxelJournal of the American Society for Mass Spectrometry, 2004
- The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compoundsRapid Communications in Mass Spectrometry, 1999