Effect of Varying Hemodynamic and Vascular Conditions on Fractional Flow Reserve: An In Vitro Study
Authors:
Open Access
- 6 July 2016
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 5 (7)
Abstract
Background: The aim of this study was to investigate the impact of varying hemodynamic conditions on fractional flow reserve (ratio of pressure distal [P d ] and proximal [P a ] to stenosis under hyperemia) in an in vitro setting. Failure to achieve maximal hyperemia and the choice of hyperemic agents may have differential effects on coronary hemodynamics and, consequently, on the determination of fractional flow reserve. Methods and Results: An in vitro flow system was developed to experimentally model the physiological coronary circulation as flow‐dependent stenosis resistance in series with variable downstream resistance. Five idealized models with 30% to 70% diameter stenosis severity were fabricated using VeroClear rigid material in an Objet260 Connex printer. Mean aortic pressure was maintained at 7 levels (60–140 mm Hg) from hypotension to hypertension using a needle valve that mimicked adjustable microcirculatory resistance. A range of physiological flow rates was applied by a steady flow pump and titrated by a flow sensor. The pressure drop and the pressure ratio (P d /P a ) were assessed for the 7 levels of aortic pressure and differing flow rates. The in vitro experimental data were coupled with pressure–flow relationships from clinical data for populations with and without myocardial infarction, respectively, to evaluate fractional flow reserve. The curve for pressure ratio and flow rate demonstrated a quadratic relationship with a decreasing slope. The absolute decrease in fractional flow reserve in the group without myocardial infarction (with myocardial infarction) was on the order of 0.03 (0.02), 0.05 (0.02), 0.07 (0.05), 0.17 (0.13) and 0.20 (0.24), respectively, for 30%, 40%, 50%, 60%, and 70% diameter stenosis, for an increase in aortic pressure from 60 to 140 mm Hg. Conclusions: The fractional flow reserve value, an index of physiological stenosis significance, was observed to decrease with increasing aortic pressure for a given stenosis in this idealized in vitro experiment for vascular groups with and without myocardial infarction.Keywords
This publication has 40 references indexed in Scilit:
- A validated predictive model of coronary fractional flow reserveJournal of The Royal Society Interface, 2011
- Coronary microvascular dysfunction after myocardial infarction: increased coronary zero flow pressure both in the infarcted and in the remote myocardium is mainly related to left ventricular filling pressureHeart, 2007
- Delineating the guide-wire flow obstruction effect in assessment of fractional flow reserve and coronary flow reserve measurementsAmerican Journal of Physiology-Heart and Circulatory Physiology, 2005
- Practice and potential pitfalls of coronary pressure measurementCatheterization and Cardiovascular Interventions, 2000
- Fluid Dynamics of a Partially Collapsible Stenosis in a Flow Model of the Coronary CirculationJournal of Biomechanical Engineering, 1996
- Effect of stenosis geometry on the Doppler-catheter gradient relation in vitro: A manifestation of pressure recoveryJACC, 1993
- Coronary flow reserve as a physiologic measure of stenosis severityJACC, 1990
- Assessment of coronary stenoses by myocardial perfusion imaging during pharmacologic coronary vasodilation. VII. Validation of coronary flow reserve as a single integrated functional measure of stenosis severity reflecting all its geometric dimensionsJACC, 1986
- Wall vibrations induced by flow through simulated stenoses in models and arteriesJournal of Biomechanics, 1977
- Physiologic basis for assessing critical coronary stenosisThe American Journal of Cardiology, 1974